Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2016 |
Principal Product | Pharmaceuticals |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | <$500,000 |
# of Employees | 260 |
Plant Area (Sq.Ft.) | 570,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 5,000 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,395,119 | 21,915,639 | kWh | $0.06 |
Electricity Demand | $556,698 | 49,574 | kW-months/year | $11.23 |
Electricity Fees | $685 | - | $ | - |
Natural Gas | $661,508 | 115,823 | MMBtu | $5.71 |
TOTAL ENERGY COSTS | $2,614,010 | |||
RECOMMENDED SAVINGS* | $591,117 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $481,517 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,270 Cost: $60 |
$1,270 | 19,868 | - | - | - | - | - | - |
$1,270 19,868 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7314 REDUCE VENTILATION AIR |
Savings: $310,823 Cost: $38,750 |
$75,023 | 1,172,244 | - | - | $235,800 | 41,296 | - | - |
$75,023 1,172,244 kWh |
- - kW-months/year |
$235,800 41,296 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,940 Cost: $1,480 |
- | - | - | - | $7,940 | 1,390 | - | - |
- - kWh |
- - kW-months/year |
$7,940 1,390 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $13,830 Cost: $11,600 |
- | - | - | - | - | - | $13,830 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$13,830 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING |
Savings: $54,090 Cost: $104,500 |
$54,090 | 845,131 | - | - | - | - | - | - |
$54,090 845,131 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $86,560 Cost: $331,000 |
$86,560 | 1,352,560 | - | - | - | - | - | - |
$86,560 1,352,560 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $96,070 Cost: $380,000 |
$65,750 | 1,027,290 | $30,320 | 2,700 | - | - | - | - |
$65,750 1,027,290 kWh |
$30,320 2,700 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR |
Savings: $20,534 Cost: $96,100 |
$10,850 | 169,563 | - | - | $9,684 | 1,696 | - | - |
$10,850 169,563 kWh |
- - kW-months/year |
$9,684 1,696 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $591,117 Cost: $963,490 |
$293,543 | 4,586,656 | $30,320 | 2,700 | $253,424 | 44,382 | $13,830 | - | $293,543 4,586,656 kWh |
$30,320 2,700 kW-months/year |
$253,424 44,382 MMBtu |
$13,830 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $481,517 Cost: $619,350 |
$205,713 | 3,214,228 | $30,320 | 2,700 | $245,484 | 42,992 | - | - | $205,713 3,214,228 kWh |
$30,320 2,700 kW-months/year |
$245,484 42,992 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |