Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2016 |
Principal Product | Textiles |
NAICS | 315210 - Cut and Sew Apparel Contractors |
SIC | 2395 - Pleating And Stitching |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 130,000 Pieces |
Production Hrs. Annual | 5,902 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $189,432 | 2,808,960 | kWh | $0.07 |
Electricity Demand | $122,820 | 6,861 | kW-months/year | $17.90 |
Electricity Fees | $13,896 | - | $ | - |
Natural Gas | $268,209 | 47,631 | MMBtu | $5.63 |
TOTAL ENERGY COSTS | $687,237 | |||
RECOMMENDED SAVINGS* | $118,177 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $54,362 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,099 Cost: $4,200 |
- | - | - | - | $4,099 | 728 |
- - kWh |
- - kW-months/year |
$4,099 728 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,895 Cost: $16,550 |
$7,706 | 115,020 | $4,189 | 234 | - | - |
$7,706 115,020 kWh |
$4,189 234 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,405 Cost: $3,610 |
$1,564 | 23,350 | $841 | 47 | - | - |
$1,564 23,350 kWh |
$841 47 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,603 Cost: $5,470 |
$1,225 | 18,290 | $1,378 | 77 | - | - |
$1,225 18,290 kWh |
$1,378 77 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,000 Cost: $13,010 |
$2,688 | 40,115 | $3,312 | 185 | - | - |
$2,688 40,115 kWh |
$3,312 185 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $8,529 Cost: $21,200 |
- | - | - | - | $8,529 | 1,515 |
- - kWh |
- - kW-months/year |
$8,529 1,515 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $33,048 Cost: $85,000 |
- | - | - | - | $33,048 | 5,870 |
- - kWh |
- - kW-months/year |
$33,048 5,870 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $40,226 Cost: $107,360 |
- | - | - | - | $40,226 | 7,145 |
- - kWh |
- - kW-months/year |
$40,226 7,145 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,556 Cost: $36,400 |
$5,549 | 82,820 | $3,007 | 168 | - | - |
$5,549 82,820 kWh |
$3,007 168 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $816 Cost: $4,560 |
- | - | - | - | $816 | 145 |
- - kWh |
- - kW-months/year |
$816 145 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $118,177 Cost: $297,360 |
$18,732 | 279,595 | $12,727 | 711 | $86,718 | 15,403 | $18,732 279,595 kWh |
$12,727 711 kW-months/year |
$86,718 15,403 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $54,362 Cost: $124,590 |
$11,619 | 173,425 | $8,879 | 496 | $33,864 | 6,015 | $11,619 173,425 kWh |
$8,879 496 kW-months/year |
$33,864 6,015 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |