Principal Product Textiles
NAICS 315210 - Cut and Sew Apparel Contractors
SIC 2395 - Pleating And Stitching
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 60,000
Annual Production 130,000 Pieces
Production Hrs. Annual 5,902
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $189,432 2,808,960 kWh $0.07
Electricity Demand $122,820 6,861 kW-months/year $17.90
Electricity Fees $13,896 - $ -
Natural Gas $268,209 47,631 MMBtu $5.63
TOTAL ENERGY COSTS $687,237
RECOMMENDED SAVINGS* $118,177 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $54,362
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$4,099
Cost:
$4,200
- - - - $4,099 728 -
-
kWh
-
-
kW-months/year
$4,099
728
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$11,895
Cost:
$16,550
$7,706 115,020 $4,189 234 - - $7,706
115,020
kWh
$4,189
234
kW-months/year
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,405
Cost:
$3,610
$1,564 23,350 $841 47 - - $1,564
23,350
kWh
$841
47
kW-months/year
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,603
Cost:
$5,470
$1,225 18,290 $1,378 77 - - $1,225
18,290
kWh
$1,378
77
kW-months/year
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,000
Cost:
$13,010
$2,688 40,115 $3,312 185 - - $2,688
40,115
kWh
$3,312
185
kW-months/year
-
-
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$8,529
Cost:
$21,200
- - - - $8,529 1,515 -
-
kWh
-
-
kW-months/year
$8,529
1,515
MMBtu
07: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$33,048
Cost:
$85,000
- - - - $33,048 5,870 -
-
kWh
-
-
kW-months/year
$33,048
5,870
MMBtu
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$40,226
Cost:
$107,360
- - - - $40,226 7,145 -
-
kWh
-
-
kW-months/year
$40,226
7,145
MMBtu
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,556
Cost:
$36,400
$5,549 82,820 $3,007 168 - - $5,549
82,820
kWh
$3,007
168
kW-months/year
-
-
MMBtu
10: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$816
Cost:
$4,560
- - - - $816 145 -
-
kWh
-
-
kW-months/year
$816
145
MMBtu
TOTAL RECOMMENDED Savings:
$118,177
Cost:
$297,360
$18,732 279,595 $12,727 711 $86,718 15,403 $18,732
279,595
kWh
$12,727
711
kW-months/year
$86,718
15,403
MMBtu
TOTAL IMPLEMENTED Savings:
$54,362
Cost:
$124,590
$11,619 173,425 $8,879 496 $33,864 6,015 $11,619
173,425
kWh
$8,879
496
kW-months/year
$33,864
6,015
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas