IAC logo
IAC Assessment: DL0199
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: DL0199
IAC Center University of Delaware
Assessment Year 2021
Principal Product Uniforms and Garments
NAICS 315280 - Other Cut and Sew Apparel Manufacturing
SIC 2389 - Apparel And Accessories, Nec
Sales $1,000,000-$5,000,000
# of Employees 69
Plant Area (Sq.Ft.) 40,000
Annual Production 83,000 Units
Production Hrs. Annual 2,856
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $30,523 392,682 kWh $0.08
Electricity Demand $9,173 2,308 kW-months/year $3.97
Natural Gas $71,915 12,387 MMBtu $5.81
TOTAL ENERGY COSTS $111,611
RECOMMENDED SAVINGS* $37,000 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage
$ kWh $ MMBtu $ Tgal
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$1,226
Cost:
-
$1,226 12,137 - - - - $1,226
12,137
kWh
-
-
MMBtu
-
-
Tgal
02: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,784
Cost:
-
- - $1,784 307 - - -
-
kWh
$1,784
307
MMBtu
-
-
Tgal
03: 2.1132 REPAIR FAULTY LOUVERS AND DAMPERS Savings:
$2,440
Cost:
$2,275
- - $2,440 420 - - -
-
kWh
$2,440
420
MMBtu
-
-
Tgal
04: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES Savings:
$2,657
Cost:
$1,514
- - $895 155 $1,762 108 -
-
kWh
$895
155
MMBtu
$1,762
108
Tgal
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$341
Cost:
$805
$341 3,374 - - - - $341
3,374
kWh
-
-
MMBtu
-
-
Tgal
06: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$296
Cost:
$20
$296 2,931 - - - - $296
2,931
kWh
-
-
MMBtu
-
-
Tgal
07: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$280
Cost:
$1,170
- - $280 48 - - -
-
kWh
$280
48
MMBtu
-
-
Tgal
08: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$272
Cost:
$1,000
- - $272 47 - - -
-
kWh
$272
47
MMBtu
-
-
Tgal
09: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$988
Cost:
$3,000
- - $988 170 - - -
-
kWh
$988
170
MMBtu
-
-
Tgal
10: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$2,675
Cost:
$7,837
- - $2,675 460 - - -
-
kWh
$2,675
460
MMBtu
-
-
Tgal
11: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR Savings:
$7,626
Cost:
$20,387
- - $7,626 1,313 - - -
-
kWh
$7,626
1,313
MMBtu
-
-
Tgal
12: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS Savings:
$10,836
Cost:
$5,559
- - $10,836 1,865 - - -
-
kWh
$10,836
1,865
MMBtu
-
-
Tgal
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,579
Cost:
$2,106
$5,579 55,236 - - - - $5,579
55,236
kWh
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$37,000
Cost:
$45,673
$7,442 73,678 $27,796 4,785 $1,762 108 $7,442
73,678
kWh
$27,796
4,785
MMBtu
$1,762
108
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ MMBtu $ Tgal
Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage