Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2022 |
Principal Product | Paper-backed foam sheets and rolls |
NAICS | 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 149 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 25,900 Thousand Feet |
Production Hrs. Annual | 8,568 |
Location (State) | DE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,840 | 2,063,711 | kWh | $0.05 |
Electricity Demand | $45,258 | 4,092 | kW-months/year | $11.06 |
Electricity Fees | $7,898 | - | $ | - |
Natural Gas | $55,837 | 6,144 | MMBtu | $9.09 |
TOTAL ENERGY COSTS | $203,833 | |||
RECOMMENDED SAVINGS* | $75,273 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1132 REPAIR FAULTY LOUVERS AND DAMPERS |
Savings: $20,616 Cost: $975 |
- | - | - | - | $20,616 | 2,268 |
- - kWh |
- - kW-months/year |
$20,616 2,268 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,912 Cost: $5,000 |
$3,323 | 72,241 | $1,589 | 144 | - | - |
$3,323 72,241 kWh |
$1,589 144 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $634 Cost: $495 |
$73 | 1,575 | $35 | 3 | $527 | 58 |
$73 1,575 kWh |
$35 3 kW-months/year |
$527 58 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,199 Cost: $6,100 |
- | - | - | - | $5,199 | 572 |
- - kWh |
- - kW-months/year |
$5,199 572 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $3,655 Cost: $5,200 |
- | - | - | - | $3,655 | 402 |
- - kWh |
- - kW-months/year |
$3,655 402 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $692 Cost: $2,233 |
- | - | - | - | $692 | 76 |
- - kWh |
- - kW-months/year |
$692 76 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $11,396 Cost: $21,500 |
$7,709 | 167,584 | $3,687 | 333 | - | - |
$7,709 167,584 kWh |
$3,687 333 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,587 Cost: $13,450 |
$5,133 | 111,580 | $2,454 | 222 | - | - |
$5,133 111,580 kWh |
$2,454 222 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $278 Cost: $210 |
$189 | 4,094 | $89 | 8 | - | - |
$189 4,094 kWh |
$89 8 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20,304 Cost: $22,424 |
$13,735 | 298,585 | $6,569 | 593 | - | - |
$13,735 298,585 kWh |
$6,569 593 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $75,273 Cost: $77,587 |
$30,162 | 655,659 | $14,423 | 1,303 | $30,689 | 3,376 | $30,162 655,659 kWh |
$14,423 1,303 kW-months/year |
$30,689 3,376 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||