Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2024
Principal Product Corrugated Paper
NAICS 322211 - Corrugated and Solid Fiber Box Manufacturing
SIC 2679 - Converted Paper Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 154
Plant Area (Sq.Ft.) 215,000
Annual Production 634,000 Thousand Feet
Production Hrs. Annual 6,400
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $714,467 6,069,577 kWh $0.12
Electricity Demand $180,581 11,785 kW-months/year $15.32
Electricity Fees $5,965 - $ -
Natural Gas $393,363 57,744 MMBtu $6.81
TOTAL ENERGY COSTS $1,294,376
RECOMMENDED SAVINGS* $449,475 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Usage One-time Revenue or Avoided Cost Electricity Usage Natural Gas Water Usage One-time Revenue or Avoided Cost
$ kWh $ MMBtu $ Tgal $ $
01: 2.2127 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM Savings:
$6,357
Cost:
$1,000
- - $5,421 796 $936 73 - - -
-
kWh
$5,421
796
MMBtu
$936
73
Tgal
-
-
$
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$6,768
Cost:
-
$6,768 57,352 - - - - - - $6,768
57,352
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$22,165
Cost:
$5,000
$22,165 187,840 - - - - - - $22,165
187,840
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$52,278
Cost:
$20,000
$52,278 443,034 - - - - - - $52,278
443,034
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
05: 3.4155 METER WASTE WATER Savings:
$7,907
Cost:
$2,000
- - - - - - $7,907 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$7,907
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$354,000
Cost:
$3,000,000
$354,000 3,000,000 - - - - - - $354,000
3,000,000
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$449,475
Cost:
$3,028,000
$435,211 3,688,226 $5,421 796 $936 73 $7,907 - $435,211
3,688,226
kWh
$5,421
796
MMBtu
$936
73
Tgal
$7,907
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ MMBtu $ Tgal $ $
Electricity Usage Natural Gas Water Usage One-time Revenue or Avoided Cost Electricity Usage Natural Gas Water Usage One-time Revenue or Avoided Cost