Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Delaware |
---|---|
Assessment Year | 2025 |
Principal Product | Concrete components |
NAICS | 327390 - Other Concrete Product Manufacturing |
SIC | 3272 - Concrete Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 77,000 |
Annual Production | 19,200 Tons |
Production Hrs. Annual | 3,850 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $56,356 | 542,352 | kWh | $0.10 |
Electricity Demand | $8,724 | 2,169 | kW-months/year | $4.02 |
Electricity Fees | $1,968 | - | $ | - |
LPG | $32,545 | 1,789 | MMBtu | $18.19 |
Fuel Oil #1 | $15,076 | 380 | MMBtu | $39.69 |
TOTAL ENERGY COSTS | $114,669 | |||
RECOMMENDED SAVINGS* | $29,007 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Fuel Oil #1 | Electricity Usage | Electricity Demand | LPG | Fuel Oil #1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $2,231 Cost: - |
$2,100 | 20,192 | $131 | 32 | - | - | - | - |
$2,100 20,192 kWh |
$131 32 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $2,414 Cost: - |
$1,661 | 15,974 | $244 | 61 | $509 | 28 | - | - |
$1,661 15,974 kWh |
$244 61 kW-months/year |
$509 28 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,824 Cost: - |
$1,590 | 15,287 | $234 | 58 | - | - | - | - |
$1,590 15,287 kWh |
$234 58 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,180 Cost: $1,075 |
$1,023 | 9,832 | $157 | 37 | - | - | - | - |
$1,023 9,832 kWh |
$157 37 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2134 ELIMINATE LEAKS IN HIGH PRESSURE REDUCING STATIONS |
Savings: $386 Cost: $1,750 |
$335 | 3,224 | $51 | 12 | - | - | - | - |
$335 3,224 kWh |
$51 12 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,096 Cost: $13,500 |
$950 | 9,130 | $146 | 35 | - | - | - | - |
$950 9,130 kWh |
$146 35 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5112 REPROCESS SPENT OILS ON SITE FOR RE-USE |
Savings: $1,561 Cost: $16,500 |
- | - | - | - | $1,561 | 87 | - | - |
- - kWh |
- - kW-months/year |
$1,561 87 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $10,284 Cost: $6,448 |
- | - | - | - | $(-4,792) | (-266) | $15,076 | 380 |
- - kWh |
- - kW-months/year |
$(-4,792) (-266) MMBtu |
$15,076 380 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,031 Cost: $7,046 |
$6,963 | 66,950 | $1,068 | 253 | - | - | - | - |
$6,963 66,950 kWh |
$1,068 253 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,007 Cost: $46,319 |
$14,622 | 140,589 | $2,031 | 489 | $(-2,722) | (-151) | $15,076 | 380 | $14,622 140,589 kWh |
$2,031 489 kW-months/year |
$(-2,722) (-151) MMBtu |
$15,076 380 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||