Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | South Dakota State |
---|---|
Assessment Year | 1996 |
Principal Product | Polyethylene and Fiberglass Tanks |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 113,000 |
Annual Production | 60,000 Pieces |
Production Hrs. Annual | 4,472 |
Location (State) | SD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $53,497 | 1,745,311 | kWh | $0.03 |
Electricity Demand | $51,228 | 6,984 | kW-months/year | $7.34 |
Electricity Fees | $8,772 | - | $ | - |
Natural Gas | $41,999 | 11,994 | MMBtu | $3.50 |
LPG | $64,904 | 9,525 | MMBtu | $6.81 |
TOTAL ENERGY COSTS | $247,400 | |||
RECOMMENDED SAVINGS* | $41,971 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,857 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,348 Cost: $1,700 |
- | - | - | - | $2,348 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,348 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,487 Cost: $21,753 |
$3,232 | 104,338 | $2,255 | 294 | - | - | - | - | - | - |
$3,232 104,338 kWh |
$2,255 294 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,576 Cost: $8,500 |
$643 | 20,809 | - | - | - | - | $7,933 | 2,267 | - | - |
$643 20,809 kWh |
- - kW-months/year |
- - $ |
$7,933 2,267 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $21,114 Cost: - |
- | - | - | - | - | - | - | - | $21,114 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$21,114 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $2,926 Cost: $150 |
- | - | - | - | - | - | $2,926 | 836 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,926 836 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,520 Cost: - |
- | - | - | - | - | - | $1,520 | 606 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,520 606 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,971 Cost: $32,103 |
$3,875 | 125,147 | $2,255 | 294 | $2,348 | - | $12,379 | 3,709 | $21,114 | - | $3,875 125,147 kWh |
$2,255 294 kW-months/year |
$2,348 - $ |
$12,379 3,709 MMBtu |
$21,114 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,857 Cost: $32,103 |
$3,875 | 125,147 | $2,255 | 294 | $2,348 | - | $12,379 | 3,709 | - | - | $3,875 125,147 kWh |
$2,255 294 kW-months/year |
$2,348 - $ |
$12,379 3,709 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |