Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | South Dakota State |
---|---|
Assessment Year | 1997 |
Principal Product | Portable Air Compressors |
NAICS | n/a |
SIC | 3563 - Air And Gas Compressors |
Sales | $50,000,000-$100,000,000 |
# of Employees | 215 |
Plant Area (Sq.Ft.) | 239,000 |
Annual Production | 250,000 Pieces |
Production Hrs. Annual | 2,600 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $143,590 | 2,811,548 | kWh | $0.05 |
Electricity Fees | $762 | - | $ | - |
Natural Gas | $83,284 | 17,659 | MMBtu | $4.72 |
TOTAL ENERGY COSTS | $231,870 | |||
RECOMMENDED SAVINGS* | $74,996 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,645 |
#|Description |
Savings Cost |
Status | Electricity Usage | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,443 Cost: $14,485 |
$4,443 | 87,046 | - | - | - | - |
$4,443 87,046 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,902 Cost: $400 |
$6,902 | 135,404 | - | - | - | - |
$6,902 135,404 kWh |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $300 Cost: - |
- | - | - | - | $300 | - |
- - kWh |
- - lb |
$300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.7131 USE A RAG RECYCLE SERVICE |
Savings: $3,351 Cost: $750 |
- | - | $3,351 | 24,000 | - | - |
- - kWh |
$3,351 24,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $60,000 Cost: $16,000 |
- | - | - | - | $60,000 | - |
- - kWh |
- - lb |
$60,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $74,996 Cost: $31,635 |
$11,345 | 222,450 | $3,351 | 24,000 | $60,300 | - | $11,345 222,450 kWh |
$3,351 24,000 lb |
$60,300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,645 Cost: $14,885 |
$11,345 | 222,450 | - | - | $300 | - | $11,345 222,450 kWh |
- - lb |
$300 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Solid Waste (non-haz) | Administrative Changes |