Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | South Dakota State |
---|---|
Assessment Year | 2000 |
Principal Product | Fire and Gas Detection Products |
NAICS | n/a |
SIC | 3669 - Communications Equipment, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 45,000 Pieces |
Production Hrs. Annual | 4,576 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $113,633 | 3,102,579 | kWh | $0.04 |
Electricity Demand | $54,834 | 7,164 | kW-months/year | $7.65 |
Electricity Fees | $18,044 | - | $ | - |
Natural Gas | $24,349 | 4,972 | MMBtu | $4.90 |
LPG | $576 | 45 | MMBtu | $12.80 |
TOTAL ENERGY COSTS | $215,227 | |||
RECOMMENDED SAVINGS* | $17,279 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,771 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,907 Cost: $8,927 |
$5,382 | 145,662 | $2,525 | 330 | - | - | - | - | - | - | - | - |
$5,382 145,662 kWh |
$2,525 330 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $569 Cost: $864 |
$569 | 15,240 | - | - | - | - | - | - | - | - | - | - |
$569 15,240 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,033 Cost: $2,718 |
$1,033 | 27,843 | - | - | - | - | - | - | - | - | - | - |
$1,033 27,843 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $721 Cost: $1,770 |
- | - | - | - | $721 | 147 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$721 147 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $1,262 Cost: $4,230 |
- | - | - | - | - | - | $1,262 | 29,200 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,262 29,200 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $1,287 Cost: $450 |
- | - | - | - | - | - | - | - | $1,287 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$1,287 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $4,500 Cost: $17,260 |
- | - | - | - | - | - | - | - | - | - | $4,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$4,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,279 Cost: $36,219 |
$6,984 | 188,745 | $2,525 | 330 | $721 | 147 | $1,262 | 29,200 | $1,287 | - | $4,500 | - | $6,984 188,745 kWh |
$2,525 330 kW-months/year |
$721 147 MMBtu |
$1,262 29,200 lb |
$1,287 - $ |
$4,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,771 Cost: $16,739 |
$6,984 | 188,745 | $2,525 | 330 | - | - | $1,262 | 29,200 | - | - | - | - | $6,984 188,745 kWh |
$2,525 330 kW-months/year |
- - MMBtu |
$1,262 29,200 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |