Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1983
Principal Product MILK & JUICES
NAICS n/a
SIC 2026 - Fluid Milk
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 0
Annual Production 8,925 Thousand Gallons
Production Hrs. Annual 6,120
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $80,732 2,895,955 kWh $0.03
Natural Gas $85,845 19,573 MMBtu $4.39
TOTAL ENERGY COSTS $166,577
RECOMMENDED SAVINGS* $25,753 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$11,800
Cost:
$350
- - $11,800 2,680 -
-
kWh
$11,800
2,680
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$6,087
Cost:
$12,013
- - $6,087 1,387 -
-
kWh
$6,087
1,387
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,946
Cost:
$150
- - $4,946 1,100 -
-
kWh
$4,946
1,100
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,520
Cost:
-
$1,520 54,220 - - $1,520
54,220
kWh
-
-
MMBtu
05: 2.2514 COVER OPEN TANKS Savings:
$1,400
Cost:
$150
- - $1,400 319 -
-
kWh
$1,400
319
MMBtu
TOTAL RECOMMENDED Savings:
$25,753
Cost:
$12,663
$1,520 54,220 $24,233 5,486 $1,520
54,220
kWh
$24,233
5,486
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings