Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1992
Principal Product BOUND BOOKS & JOURNALS
NAICS n/a
SIC 2731 - Book Publishing
Sales $5,000,000-$10,000,000
# of Employees 95
Plant Area (Sq.Ft.) 0
Annual Production 1,800 Tons
Production Hrs. Annual 4,240
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $115,702 1,426,143 kWh $0.08
Natural Gas $2,364 360 MMBtu $6.57
TOTAL ENERGY COSTS $118,066
RECOMMENDED SAVINGS* $7,749 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,749
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$934
Cost:
$150
$934 11,430 - - - - $934
11,430
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,100
Cost:
$8,510
$2,271 28,136 - - $(-171) - $2,271
28,136
kWh
-
-
MMBtu
$(-171)
-
$
03: 2.7122 DISCONNECT BALLASTS Savings:
$136
Cost:
$50
$136 1,758 - - - - $136
1,758
kWh
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$465
Cost:
$6,040
$1,363 16,706 - - $(-898) - $1,363
16,706
kWh
-
-
MMBtu
$(-898)
-
$
05: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN Savings:
$85
Cost:
-
- - $85 13 - - -
-
kWh
$85
13
MMBtu
-
-
$
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$3,920
Cost:
$18,300
$2,538 31,360 $1,382 210 - - $2,538
31,360
kWh
$1,382
210
MMBtu
-
-
$
07: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$109
Cost:
-
$109 1,465 - - - - $109
1,465
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$7,749
Cost:
$33,050
$7,351 90,855 $1,467 223 $(-1,069) - $7,351
90,855
kWh
$1,467
223
MMBtu
$(-1,069)
-
$
TOTAL IMPLEMENTED Savings:
$7,749
Cost:
$33,050
$7,351 90,855 $1,467 223 $(-1,069) - $7,351
90,855
kWh
$1,467
223
MMBtu
$(-1,069)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes