Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1995
Principal Product Kaolin
NAICS n/a
SIC 3295 - Minerals, Ground Or Treated
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 20,000
Annual Production 400,000 Tons
Production Hrs. Annual 8,400
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $569,847 10,453,107 kWh $0.05
Natural Gas $28,182 4,816 MMBtu $5.85
TOTAL ENERGY COSTS $598,029
RECOMMENDED SAVINGS* $150,440 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $150,440
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$82,460
Cost:
-
$82,460 - $82,460
-
kWh
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$67,980
Cost:
-
$67,980 - $67,980
-
kWh
TOTAL RECOMMENDED Savings:
$150,440
Cost:
-
$150,440 - $150,440
-
kWh
TOTAL IMPLEMENTED Savings:
$150,440
Cost:
-
$150,440 - $150,440
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage