Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1996 |
Principal Product | Nylon Yarn |
NAICS | n/a |
SIC | 2281 - Yarn Spinning Mills |
Sales | $50,000,000-$100,000,000 |
# of Employees | 650 |
Plant Area (Sq.Ft.) | 318,740 |
Annual Production | 60,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,277,028 | 50,475,382 | kWh | $0.03 |
Electricity Demand | $947,485 | 88,799 | kW-months/year | $10.67 |
Electricity Fees | $153,106 | - | $ | - |
Natural Gas | $432,627 | 124,622 | MMBtu | $3.47 |
Fuel Oil #2 | $78,545 | 18,182 | MMBtu | $4.32 |
TOTAL ENERGY COSTS | $2,916,081 | |||
RECOMMENDED SAVINGS* | $79,723 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,120 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $26,920 Cost: $147,550 |
$16,640 | 657,679 | $10,030 | 940 | $250 | - | - | - |
$16,640 657,679 kWh |
$10,030 940 kW-months/year |
$250 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $13,303 Cost: $11,440 |
$8,297 | 327,960 | $5,006 | 469 | - | - | - | - |
$8,297 327,960 kWh |
$5,006 469 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,900 Cost: - |
$1,186 | 46,893 | $674 | 67 | $40 | - | - | - |
$1,186 46,893 kWh |
$674 67 kW-months/year |
$40 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,670 Cost: $1,000 |
$3,540 | 140,094 | $2,130 | 200 | - | - | - | - |
$3,540 140,094 kWh |
$2,130 200 kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $28,300 Cost: $55,000 |
$28,300 | 1,119,285 | - | - | - | - | - | - |
$28,300 1,119,285 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4155 METER WASTE WATER |
Savings: $3,630 Cost: - |
- | - | - | - | - | - | $3,630 | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,630 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,723 Cost: $214,990 |
$57,963 | 2,291,911 | $17,840 | 1,676 | $290 | - | $3,630 | - | $57,963 2,291,911 kWh |
$17,840 1,676 kW-months/year |
$290 - $ |
$3,630 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,120 Cost: $148,550 |
$21,366 | 844,666 | $12,834 | 1,207 | $290 | - | $3,630 | - | $21,366 844,666 kWh |
$12,834 1,207 kW-months/year |
$290 - $ |
$3,630 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal |