Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1996 |
Principal Product | Packaged Salads |
NAICS | n/a |
SIC | 2035 - Pickles, Sauces, And Salad Dressings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 800,000 |
Annual Production | 52,000,000 Pounds |
Production Hrs. Annual | 4,992 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $693,334 | 29,450,176 | kWh | $0.02 |
Electricity Demand | $730,477 | 73,327 | kW-months/year | $9.96 |
Electricity Fees | $123,809 | - | $ | - |
TOTAL ENERGY COSTS | $2,098,223 | |||
RECOMMENDED SAVINGS* | $313,799 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $312,594 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $18,246 Cost: $675 |
$5,567 | 229,191 | $11,809 | 927 | $870 | - | - | - | - | - | - | - |
$5,567 229,191 kWh |
$11,809 927 kW-months/year |
$870 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $3,110 Cost: $3,500 |
$486 | 19,930 | $2,480 | 195 | $144 | - | - | - | - | - | - | - |
$486 19,930 kWh |
$2,480 195 kW-months/year |
$144 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $3,308 Cost: $103 |
$367 | 15,240 | $248 | 20 | - | - | $1,379 | 657,000 | - | - | $1,314 | - |
$367 15,240 kWh |
$248 20 kW-months/year |
- - $ |
$1,379 657,000 Tgal |
- - lb |
$1,314 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $6,090 Cost: $1,450 |
$1,863 | 76,788 | $3,939 | 309 | $288 | - | - | - | - | - | - | - |
$1,863 76,788 kWh |
$3,939 309 kW-months/year |
$288 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4155 METER WASTE WATER |
Savings: $14,720 Cost: - |
- | - | - | - | - | - | - | - | - | - | $14,720 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - lb |
$14,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,120 Cost: $4,300 |
$1,072 | 43,962 | - | - | $48 | - | - | - | - | - | - | - |
$1,072 43,962 kWh |
- - kW-months/year |
$48 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,000 Cost: $4,908 |
$3,274 | 134,818 | $2,480 | 195 | $246 | - | - | - | - | - | - | - |
$3,274 134,818 kWh |
$2,480 195 kW-months/year |
$246 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,205 Cost: $66 |
$598 | 24,619 | $535 | 42 | $72 | - | - | - | - | - | - | - |
$598 24,619 kWh |
$535 42 kW-months/year |
$72 - $ |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5317 SELL / OFFER BY-PRODUCT AS ANIMAL FEED |
Savings: $260,000 Cost: $49,800 |
- | - | - | - | - | - | - | - | $260,000 | 26,000,000 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$260,000 26,000,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $313,799 Cost: $64,802 |
$13,227 | 544,548 | $21,491 | 1,688 | $1,668 | - | $1,379 | 657,000 | $260,000 | 26,000,000 | $16,034 | - | $13,227 544,548 kWh |
$21,491 1,688 kW-months/year |
$1,668 - $ |
$1,379 657,000 Tgal |
$260,000 26,000,000 lb |
$16,034 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $312,594 Cost: $64,736 |
$12,629 | 519,929 | $20,956 | 1,646 | $1,596 | - | $1,379 | 657,000 | $260,000 | 26,000,000 | $16,034 | - | $12,629 519,929 kWh |
$20,956 1,646 kW-months/year |
$1,596 - $ |
$1,379 657,000 Tgal |
$260,000 26,000,000 lb |
$16,034 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Solid Waste (non-haz) | Ancillary Material Cost |