Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1997 |
Principal Product | Chemical Adsorbent |
NAICS | n/a |
SIC | 3564 - Blowers And Fans |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 3,300,000 Pounds |
Production Hrs. Annual | 2,300 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $19,073 | 756,741 | kWh | $0.03 |
Electricity Demand | $34,753 | 2,320 | kW-months/year | $14.98 |
Electricity Fees | $5,349 | - | $ | - |
Natural Gas | $30,071 | 5,281 | MMBtu | $5.69 |
TOTAL ENERGY COSTS | $89,246 | |||
RECOMMENDED SAVINGS* | $35,485 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,895 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $2,995 Cost: $4,380 |
$807 | 31,946 | $1,952 | 136 | $236 | - | - | - | - | - | - | - |
$807 31,946 kWh |
$1,952 136 kW-months/year |
$236 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,420 Cost: $900 |
- | - | - | - | - | - | $1,420 | 250 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,420 250 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,480 Cost: $150 |
- | - | - | - | - | - | $1,480 | 260 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,480 260 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,470 Cost: - |
$228 | 9,086 | $2,127 | 142 | $115 | - | - | - | - | - | - | - |
$228 9,086 kWh |
$2,127 142 kW-months/year |
$115 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $80 Cost: $250 |
$19 | 879 | $60 | 4 | $1 | - | - | - | - | - | - | - |
$19 879 kWh |
$60 4 kW-months/year |
$1 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.2121 CONVERT TO ELECTROSTATIC POWDER COATING |
Savings: $6,540 Cost: - |
- | - | - | - | - | - | - | - | - | - | $6,540 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$6,540 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $1,600 Cost: $1,320 |
- | - | - | - | - | - | - | - | - | - | $1,600 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$1,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $18,900 Cost: $4,000 |
- | - | - | - | - | - | - | - | $13,500 | - | $5,400 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$13,500 - $ |
$5,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,485 Cost: $11,000 |
$1,054 | 41,911 | $4,139 | 282 | $352 | - | $2,900 | 510 | $13,500 | - | $13,540 | - | $1,054 41,911 kWh |
$4,139 282 kW-months/year |
$352 - $ |
$2,900 510 MMBtu |
$13,500 - $ |
$13,540 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,895 Cost: $5,430 |
$807 | 31,946 | $1,952 | 136 | $236 | - | $2,900 | 510 | - | - | - | - | $807 31,946 kWh |
$1,952 136 kW-months/year |
$236 - $ |
$2,900 510 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost |