Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1998 |
Principal Product | Patterned Carpet |
NAICS | n/a |
SIC | 2273 - Carpets And Rugs |
Sales | $100,000,000-$500,000,000 |
# of Employees | 490 |
Plant Area (Sq.Ft.) | 342,000 |
Annual Production | 36,900,000 Thousand Feet |
Production Hrs. Annual | 7,500 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $313,362 | 8,913,247 | kWh | $0.04 |
Electricity Demand | $118,454 | 24,678 | kW-months/year | $4.80 |
Electricity Fees | $16,642 | - | $ | - |
Natural Gas | $316,073 | 62,678 | MMBtu | $5.04 |
LPG | $19,934 | 1,879 | MMBtu | $10.61 |
Fuel Oil #2 | $11,854 | 1,417 | MMBtu | $8.37 |
TOTAL ENERGY COSTS | $796,319 | |||
RECOMMENDED SAVINGS* | $224,713 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Natural Gas | LPG | Administrative Changes | Water Consumption | Natural Gas | LPG | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | MMBtu | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $65,180 Cost: $100,000 |
- | - | - | - | $65,180 | - | - | - |
- - MMBtu |
- - MMBtu |
$65,180 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $8,990 Cost: - |
- | - | - | - | $8,990 | - | - | - |
- - MMBtu |
- - MMBtu |
$8,990 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8112 COMBINE UTILITY METERS |
Savings: $41,000 Cost: - |
- | - | - | - | $41,000 | - | - | - |
- - MMBtu |
- - MMBtu |
$41,000 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $23,695 Cost: $13,000 |
$23,280 | 3,726 | - | - | - | - | $415 | - |
$23,280 3,726 MMBtu |
- - MMBtu |
- - $ |
$415 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $9,530 Cost: $12,500 |
$8,190 | 1,638 | - | - | - | - | $1,340 | - |
$8,190 1,638 MMBtu |
- - MMBtu |
- - $ |
$1,340 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $26,700 Cost: $40,500 |
$19,500 | 3,900 | - | - | $7,200 | - | - | - |
$19,500 3,900 MMBtu |
- - MMBtu |
$7,200 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $35,596 Cost: $52,700 |
$30,610 | 6,122 | - | - | $136 | - | $4,850 | - |
$30,610 6,122 MMBtu |
- - MMBtu |
$136 - $ |
$4,850 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $14,022 Cost: $27,000 |
$(-5,900) | (-1,879) | $19,922 | 1,879 | - | - | - | - |
$(-5,900) (-1,879) MMBtu |
$19,922 1,879 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $224,713 Cost: $245,700 |
$75,680 | 13,507 | $19,922 | 1,879 | $122,506 | - | $6,605 | - | $75,680 13,507 MMBtu |
$19,922 1,879 MMBtu |
$122,506 - $ |
$6,605 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - MMBtu |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | MMBtu | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Natural Gas | LPG | Administrative Changes | Water Consumption | Natural Gas | LPG | Administrative Changes | Water Consumption |