Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2000 |
Principal Product | Egg Cartons and Egg Trays |
NAICS | n/a |
SIC | 2679 - Converted Paper Products, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 343,500 |
Annual Production | 2,147,483,647 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $618,930 | 32,235,932 | kWh | $0.02 |
Electricity Demand | $615,576 | 50,402 | kW-months/year | $12.21 |
Electricity Fees | $125,319 | - | $ | - |
Natural Gas | $1,435,087 | 488,432 | MMBtu | $2.94 |
TOTAL ENERGY COSTS | $2,914,876 | |||
RECOMMENDED SAVINGS* | $240,713 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,162 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER |
Savings: $16,970 Cost: $35,000 |
$8,387 | 436,694 | $7,623 | 595 | $960 | - | - | - | - | - | - | - | - | - |
$8,387 436,694 kWh |
$7,623 595 kW-months/year |
$960 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,567 Cost: $56,336 |
$2,752 | 143,318 | $2,500 | 195 | $315 | - | - | - | - | - | - | - | - | - |
$2,752 143,318 kWh |
$2,500 195 kW-months/year |
$315 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,350 Cost: $324 |
$670 | 34,584 | $586 | 46 | $94 | - | - | - | - | - | - | - | - | - |
$670 34,584 kWh |
$586 46 kW-months/year |
$94 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $13,915 Cost: $29,000 |
$6,532 | 340,270 | $6,595 | 515 | $788 | - | - | - | - | - | - | - | - | - |
$6,532 340,270 kWh |
$6,595 515 kW-months/year |
$788 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4151 MINIMIZE WATER USAGE |
Savings: $8,289 Cost: $2,400 |
$709 | 36,928 | $645 | 50 | $81 | - | - | - | $6,854 | 4,233,600 | - | - | - | - |
$709 36,928 kWh |
$645 50 kW-months/year |
$81 - $ |
- - MMBtu |
$6,854 4,233,600 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $34,271 Cost: $19,000 |
- | - | - | - | - | - | - | - | $27,476 | 21,200,000 | - | - | $6,795 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$27,476 21,200,000 Tgal |
- - $ |
$6,795 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4151 MINIMIZE WATER USAGE |
Savings: $26,306 Cost: $7,850 |
$903 | 47,186 | $820 | 64 | $104 | - | - | - | $24,479 | 15,100,000 | - | - | - | - |
$903 47,186 kWh |
$820 64 kW-months/year |
$104 - $ |
- - MMBtu |
$24,479 15,100,000 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $39,645 Cost: $60,000 |
- | - | - | - | - | - | - | - | - | - | $36,000 | - | $3,645 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$36,000 - $ |
$3,645 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $94,400 Cost: - |
- | - | - | - | - | - | $94,400 | 32,130 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$94,400 32,130 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $240,713 Cost: $209,910 |
$19,953 | 1,038,980 | $18,769 | 1,465 | $2,342 | - | $94,400 | 32,130 | $58,809 | 40,533,600 | $36,000 | - | $10,440 | - | $19,953 1,038,980 kWh |
$18,769 1,465 kW-months/year |
$2,342 - $ |
$94,400 32,130 MMBtu |
$58,809 40,533,600 Tgal |
$36,000 - $ |
$10,440 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,162 Cost: $66,586 |
$4,364 | 227,432 | $3,965 | 309 | $500 | - | - | - | $31,333 | 19,333,600 | - | - | - | - | $4,364 227,432 kWh |
$3,965 309 kW-months/year |
$500 - $ |
- - MMBtu |
$31,333 19,333,600 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost |