Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2001 |
Principal Product | Speakers |
NAICS | n/a |
SIC | 3931 - Musical Instruments |
Sales | $50,000,000-$100,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 274,865 |
Annual Production | 150,500 Pieces |
Production Hrs. Annual | 2,200 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $248,921 | 6,274,267 | kWh | $0.04 |
Electricity Demand | $162,106 | 19,902 | kW-months/year | $8.15 |
Electricity Fees | $24,661 | - | $ | - |
Natural Gas | $96,327 | 11,085 | MMBtu | $8.69 |
TOTAL ENERGY COSTS | $550,693 | |||
RECOMMENDED SAVINGS* | $128,058 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,522 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Administrative Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $22,943 Cost: - |
- | - | $22,943 | 2,044 | - | - | - | - | - | - | - | - |
- - kWh |
$22,943 2,044 kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $2,767 Cost: - |
- | - | - | - | $2,767 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,767 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,175 Cost: $200 |
$2,787 | 58,950 | $2,098 | 283 | $290 | - | - | - | - | - | - | - |
$2,787 58,950 kWh |
$2,098 283 kW-months/year |
$290 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,580 Cost: $3,750 |
$4,516 | 108,000 | $4,524 | 576 | $540 | - | - | - | - | - | - | - |
$4,516 108,000 kWh |
$4,524 576 kW-months/year |
$540 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,350 Cost: $840 |
- | - | $2,215 | 168 | $135 | - | - | - | - | - | - | - |
- - kWh |
$2,215 168 kW-months/year |
$135 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $77,243 Cost: $235,000 |
$(-3,279) | (-110,000) | $(-2,826) | (-600) | - | - | $18,678 | 3,600,000 | - | - | $64,670 | - |
$(-3,279) (-110,000) kWh |
$(-2,826) (-600) kW-months/year |
- - $ |
$18,678 3,600,000 lb |
- - $ |
$64,670 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $8,000 Cost: $5,000 |
- | - | - | - | - | - | $18,678 | 3,600,000 | $(-10,678) | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$18,678 3,600,000 lb |
$(-10,678) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $128,058 Cost: $244,790 |
$4,024 | 56,950 | $28,954 | 2,471 | $3,732 | - | $37,356 | 7,200,000 | $(-10,678) | - | $64,670 | - | $4,024 56,950 kWh |
$28,954 2,471 kW-months/year |
$3,732 - $ |
$37,356 7,200,000 lb |
$(-10,678) - $ |
$64,670 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,522 Cost: $3,950 |
$7,303 | 166,950 | $6,622 | 859 | $3,597 | - | - | - | - | - | - | - | $7,303 166,950 kWh |
$6,622 859 kW-months/year |
$3,597 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Administrative Changes | By-product Production |