Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2001 |
Principal Product | Tapestry Products |
NAICS | n/a |
SIC | 2392 - Housefurnishings, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 483 |
Plant Area (Sq.Ft.) | 372,000 |
Annual Production | 6,500,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $156,106 | 5,866,000 | kWh | $0.03 |
Electricity Demand | $95,245 | 1,725 | kW-months/year | $55.21 |
Electricity Fees | $97,747 | - | $ | - |
Natural Gas | $294,672 | 41,362 | MMBtu | $7.12 |
TOTAL ENERGY COSTS | $711,366 | |||
RECOMMENDED SAVINGS* | $141,559 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $141,559 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3512 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY |
Savings: $21,103 Cost: $60,000 |
$6,671 | 87,600 | $4,793 | 1,005 | $9,639 | - | - | - | - | - |
$6,671 87,600 kWh |
$4,793 1,005 kW-months/year |
$9,639 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $35,140 Cost: $68,913 |
$29,489 | 708,596 | $4,635 | 81 | $1,016 | - | - | - | - | - |
$29,489 708,596 kWh |
$4,635 81 kW-months/year |
$1,016 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,660 Cost: $825 |
$4,470 | 107,400 | $1,024 | 18 | $166 | - | - | - | - | - |
$4,470 107,400 kWh |
$1,024 18 kW-months/year |
$166 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,036 Cost: $350 |
$818 | 19,650 | $188 | 3 | $30 | - | - | - | - | - |
$818 19,650 kWh |
$188 3 kW-months/year |
$30 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $76,655 Cost: - |
- | - | - | - | - | - | $69,515 | 386,200 | $7,140 | - |
- - kWh |
- - kW-months/year |
- - $ |
$69,515 386,200 lb |
$7,140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,965 Cost: $1,418 |
$1,141 | 27,417 | $767 | 13 | $57 | - | - | - | - | - |
$1,141 27,417 kWh |
$767 13 kW-months/year |
$57 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $141,559 Cost: $131,506 |
$42,589 | 950,663 | $11,407 | 1,120 | $10,908 | - | $69,515 | 386,200 | $7,140 | - | $42,589 950,663 kWh |
$11,407 1,120 kW-months/year |
$10,908 - $ |
$69,515 386,200 lb |
$7,140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $141,559 Cost: $131,506 |
$42,589 | 950,663 | $11,407 | 1,120 | $10,908 | - | $69,515 | 386,200 | $7,140 | - | $42,589 950,663 kWh |
$11,407 1,120 kW-months/year |
$10,908 - $ |
$69,515 386,200 lb |
$7,140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Ancillary Material Cost |