Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2002 |
Principal Product | yellow pine lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 64,000,000 Thousand Feet |
Production Hrs. Annual | 2,340 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $312,076 | 6,056,388 | kWh | $0.05 |
Natural Gas | $671 | 61 | MMBtu | $11.00 |
Wood | $88,266 | 250,720 | MMBtu | $0.35 |
TOTAL ENERGY COSTS | $468,131 | |||
RECOMMENDED SAVINGS* | $2,196,973 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Wood | Water Disposal | Administrative Changes | Primary Product | Electricity Usage | Wood | Water Disposal | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8112 COMBINE UTILITY METERS |
Savings: $13,100 Cost: $1,000 |
- | - | - | - | - | - | $13,100 | - | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
$13,100 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $45,343 Cost: $49,000 |
$45,343 | 824,443 | - | - | - | - | - | - | - | - |
$45,343 824,443 kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2693 USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION |
Savings: $56,762 Cost: $237,300 |
$56,762 | 293,083 | - | - | - | - | - | - | - | - |
$56,762 293,083 kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $22,495 Cost: $2,500 |
- | - | $22,495 | 30,139 | - | - | - | - | - | - |
- - kWh |
$22,495 30,139 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,965 Cost: $14,670 |
$6,965 | 139,215 | - | - | - | - | - | - | - | - |
$6,965 139,215 kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $51,992 Cost: $57,500 |
$1,918 | 34,584 | - | - | $50,074 | 34,633,000 | - | - | - | - |
$1,918 34,584 kWh |
- - MMBtu |
$50,074 34,633,000 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $316 Cost: $1,132 |
- | - | $316 | 904 | - | - | - | - | - | - |
- - kWh |
$316 904 MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $2,000,000 Cost: $200,000 |
- | - | - | - | - | - | - | - | $2,000,000 | - |
- - kWh |
- - MMBtu |
- - Tgal |
- - $ |
$2,000,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $2,196,973 Cost: $563,102 |
$110,988 | 1,291,325 | $22,811 | 31,043 | $50,074 | 34,633,000 | $13,100 | - | $2,000,000 | - | $110,988 1,291,325 kWh |
$22,811 31,043 MMBtu |
$50,074 34,633,000 Tgal |
$13,100 - $ |
$2,000,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Wood | Water Disposal | Administrative Changes | Primary Product | Electricity Usage | Wood | Water Disposal | Administrative Changes | Primary Product |