Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2003 |
Principal Product | SOFT DRINKS |
NAICS | 312111 - Soft Drink Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | n/a |
# of Employees | 263 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 44,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $377,752 | 16,344,387 | kWh | $0.02 |
Electricity Demand | $458,867 | 35,442 | kW-months/year | $12.95 |
Natural Gas | $278,228 | 44,393 | MMBtu | $6.27 |
TOTAL ENERGY COSTS | $1,458,082 | |||
RECOMMENDED SAVINGS* | $143,273 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,388 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,490 Cost: $6,340 |
$4,320 | 186,950 | $3,170 | 257 | - | - | - | - | - | - |
$4,320 186,950 kWh |
$3,170 257 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $354 Cost: $248 |
- | - | - | - | - | - | $354 | 56 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$354 56 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,848 Cost: - |
$3,372 | 145,891 | $2,476 | 200 | - | - | - | - | - | - |
$3,372 145,891 kWh |
$2,476 200 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8112 COMBINE UTILITY METERS |
Savings: $113,960 Cost: - |
- | - | - | - | $113,960 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$113,960 - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $13,569 Cost: $12,000 |
$(-13,395) | (-218,429) | - | - | - | - | - | - | $26,964 | - |
$(-13,395) (-218,429) kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$26,964 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,050 Cost: $300 |
$605 | 26,166 | $445 | 36 | - | - | - | - | - | - |
$605 26,166 kWh |
$445 36 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $130 Cost: $50 |
$130 | 3,762 | - | - | - | - | - | - | - | - |
$130 3,762 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $872 Cost: $490 |
$872 | 37,720 | - | - | - | - | - | - | - | - |
$872 37,720 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $143,273 Cost: $19,428 |
$(-4,096) | 182,060 | $6,091 | 493 | $113,960 | - | $354 | 56 | $26,964 | - | $(-4,096) 182,060 kWh |
$6,091 493 kW-months/year |
$113,960 - $ |
$354 56 MMBtu |
$26,964 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,388 Cost: $6,640 |
$8,297 | 359,007 | $6,091 | 493 | - | - | - | - | - | - | $8,297 359,007 kWh |
$6,091 493 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Consumption |