IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2004 |
Principal Product | School Buses |
NAICS | 336211 - Motor Vehicle Body Manufacturing |
SIC | 3713 - Truck And Bus Bodies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 375 |
Plant Area (Sq.Ft.) | 295,000 |
Annual Production | 4,000 Pieces |
Production Hrs. Annual | 4,000 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $175,838 | 3,786,300 | kWh | $0.05 |
Electricity Demand | $82,509 | 9,216 | kW-months/year | $8.95 |
Electricity Fees | $12,173 | - | $ | - |
TOTAL ENERGY COSTS | $270,520 | |||
RECOMMENDED SAVINGS* | $46,723 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,405 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $15,414 Cost: $30,000 |
- | - | - | - | $15,414 | 1,551 | - | - |
- - kWh |
- - kW-months/year |
$15,414 1,551 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,785 Cost: $3,525 |
$1,785 | 48,670 | - | - | - | - | - | - |
$1,785 48,670 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $595 Cost: $765 |
$595 | 16,248 | - | - | - | - | - | - |
$595 16,248 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,306 Cost: $2,046 |
$1,098 | 30,000 | $1,208 | 90 | - | - | - | - |
$1,098 30,000 kWh |
$1,208 90 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $5,022 Cost: $3,380 |
$352 | 9,620 | $775 | 58 | - | - | $3,895 | 1,310,000 |
$352 9,620 kWh |
$775 58 kW-months/year |
- - MMBtu |
$3,895 1,310,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,490 Cost: $2,500 |
$8,490 | 232,036 | - | - | - | - | - | - |
$8,490 232,036 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $729 Cost: $1,500 |
$66 | 1,817 | - | - | $663 | 67 | - | - |
$66 1,817 kWh |
- - kW-months/year |
$663 67 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $8,773 Cost: $4,900 |
- | - | - | - | $8,773 | 772 | - | - |
- - kWh |
- - kW-months/year |
$8,773 772 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $3,609 Cost: - |
$1,892 | 46,920 | $1,717 | 282 | - | - | - | - |
$1,892 46,920 kWh |
$1,717 282 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,723 Cost: $48,616 |
$14,278 | 385,311 | $3,700 | 430 | $24,850 | 2,390 | $3,895 | 1,310,000 | $14,278 385,311 kWh |
$3,700 430 kW-months/year |
$24,850 2,390 MMBtu |
$3,895 1,310,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,405 Cost: $4,546 |
$11,480 | 308,956 | $2,925 | 372 | - | - | - | - | $11,480 308,956 kWh |
$2,925 372 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |