Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2005 |
Principal Product | Hard and Soft Candy |
NAICS | 311340 - Nonchocolate Confectionery Manufacturing |
SIC | 2064 - Candy & Other Confectionery Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 276 |
Plant Area (Sq.Ft.) | 146,800 |
Annual Production | 32,000,000 Pounds |
Production Hrs. Annual | 5,880 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $601,678 | 17,357,760 | kWh | $0.03 |
Electricity Demand | $414,881 | 35,814 | kW-months/year | $11.58 |
Electricity Fees | $18,606 | - | $ | - |
Natural Gas | $1,097,083 | 258,522 | MMBtu | $4.24 |
TOTAL ENERGY COSTS | $2,132,248 | |||
RECOMMENDED SAVINGS* | $269,648 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $250,217 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $241,590 Cost: $283,800 |
$45,570 | 1,470,000 | $30,750 | 3,000 | - | - | $185,000 | - | $(-19,730) | - |
$45,570 1,470,000 kWh |
$30,750 3,000 kW-months/year |
- - MMBtu |
$185,000 - $ |
$(-19,730) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,617 Cost: $22,400 |
$3,731 | 120,344 | $2,886 | 282 | - | - | - | - | - | - |
$3,731 120,344 kWh |
$2,886 282 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1231 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS |
Savings: $2,775 Cost: $900 |
- | - | - | - | $2,775 | 511 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,775 511 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $14,900 Cost: $25,600 |
- | - | - | - | $14,900 | 2,744 | - | - | - | - |
- - kWh |
- - kW-months/year |
$14,900 2,744 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,756 Cost: $1,785 |
$1,741 | 14,717 | $15 | 1 | - | - | - | - | - | - |
$1,741 14,717 kWh |
$15 1 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,010 Cost: $850 |
$1,200 | 38,714 | $810 | 17 | - | - | - | - | - | - |
$1,200 38,714 kWh |
$810 17 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $269,648 Cost: $335,335 |
$52,242 | 1,643,775 | $34,461 | 3,300 | $17,675 | 3,255 | $185,000 | - | $(-19,730) | - | $52,242 1,643,775 kWh |
$34,461 3,300 kW-months/year |
$17,675 3,255 MMBtu |
$185,000 - $ |
$(-19,730) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $250,217 Cost: $307,050 |
$50,501 | 1,629,058 | $34,446 | 3,299 | - | - | $185,000 | - | $(-19,730) | - | $50,501 1,629,058 kWh |
$34,446 3,299 kW-months/year |
- - MMBtu |
$185,000 - $ |
$(-19,730) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Water Consumption |