Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2008
Principal Product Gear Pumps
NAICS 333911 - Pump and Pumping Equipment Manufacturing
SIC 3561 - Pumps And Pumping Equipment
Sales $10,000,000-$50,000,000
# of Employees 215
Plant Area (Sq.Ft.) 156,040
Annual Production 32,400 Pieces
Production Hrs. Annual 8,760
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $375,113 7,964,179 kWh $0.05
Electricity Demand $213,636 17,132 kW-months/year $12.47
Electricity Fees $47,190 - $ -
Natural Gas $131,134 9,180 MMBtu $14.28
TOTAL ENERGY COSTS $767,073
RECOMMENDED SAVINGS* $127,768 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $54,768
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$24,327
Cost:
$3,500
$17,892 380,680 $6,435 516 - - $17,892
380,680
kWh
$6,435
516
kW-months/year
-
-
MMBtu
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,774
Cost:
-
$3,502 74,500 $1,272 102 - - $3,502
74,500
kWh
$1,272
102
kW-months/year
-
-
MMBtu
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$9,073
Cost:
$9,000
- - - - $9,073 643 -
-
kWh
-
-
kW-months/year
$9,073
643
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$790
Cost:
$2,775
- - - - $790 56 -
-
kWh
-
-
kW-months/year
$790
56
MMBtu
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$9,500
Cost:
$15,600
$9,500 202,167 - - - - $9,500
202,167
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT Savings:
$22,600
Cost:
$60,000
- - - - $22,600 1,602 -
-
kWh
-
-
kW-months/year
$22,600
1,602
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$25,667
Cost:
$37,500
$20,639 438,190 $5,028 403 - - $20,639
438,190
kWh
$5,028
403
kW-months/year
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$31,037
Cost:
$64,132
$20,578 437,835 $10,459 839 - - $20,578
437,835
kWh
$10,459
839
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$127,768
Cost:
$192,507
$72,111 1,533,372 $23,194 1,860 $32,463 2,301 $72,111
1,533,372
kWh
$23,194
1,860
kW-months/year
$32,463
2,301
MMBtu
TOTAL IMPLEMENTED Savings:
$54,768
Cost:
$41,000
$42,033 893,370 $12,735 1,021 - - $42,033
893,370
kWh
$12,735
1,021
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas