Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2009 |
Principal Product | Resilient Flooring |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3996 - Hard Surface Floor Coverings, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 62 |
Plant Area (Sq.Ft.) | 73,000 |
Annual Production | 19,000 Thousand Feet |
Production Hrs. Annual | 5,952 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $183,892 | 3,536,390 | kWh | $0.05 |
Electricity Demand | $77,738 | 9,112 | kW-months/year | $8.53 |
Natural Gas | $286,342 | 18,715 | MMBtu | $15.30 |
TOTAL ENERGY COSTS | $547,972 | |||
RECOMMENDED SAVINGS* | $52,392 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,185 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $7,130 Cost: $2,100 |
- | - | - | - | $7,130 | 466 |
- - kWh |
- - kW-months/year |
$7,130 466 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $352 Cost: - |
$254 | 4,880 | $98 | 10 | - | - |
$254 4,880 kWh |
$98 10 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,117 Cost: $890 |
$743 | 14,298 | $374 | 38 | - | - |
$743 14,298 kWh |
$374 38 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,201 Cost: $900 |
$3,753 | 72,175 | $1,448 | 145 | - | - |
$3,753 72,175 kWh |
$1,448 145 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,586 Cost: $42,920 |
$8,356 | 160,700 | $3,230 | 324 | - | - |
$8,356 160,700 kWh |
$3,230 324 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $23,715 Cost: $17,250 |
- | - | - | - | $23,715 | 1,550 |
- - kWh |
- - kW-months/year |
$23,715 1,550 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,291 Cost: $4,515 |
$2,059 | 39,600 | $1,232 | 124 | - | - |
$2,059 39,600 kWh |
$1,232 124 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $52,392 Cost: $68,575 |
$15,165 | 291,653 | $6,382 | 641 | $30,845 | 2,016 | $15,165 291,653 kWh |
$6,382 641 kW-months/year |
$30,845 2,016 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,185 Cost: $45,910 |
$9,353 | 179,878 | $3,702 | 372 | $7,130 | 466 | $9,353 179,878 kWh |
$3,702 372 kW-months/year |
$7,130 466 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |