IAC logo
IAC Assessment: GT0879
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0879
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2011
Principal Product Nickel Cadmium Batteries
NAICS 335911 - Storage Battery Manufacturing
SIC 3691 - Storage Batteries
Sales $50,000,000-$100,000,000
# of Employees 220
Plant Area (Sq.Ft.) 206,000
Annual Production 11,000 Pieces
Production Hrs. Annual 8,760
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $786,132 12,355,038 kWh $0.06
Electricity Fees $93,641 - $ -
Natural Gas $217,713 65,741 MMBtu $3.31
TOTAL ENERGY COSTS $1,097,486
RECOMMENDED SAVINGS* $413,588 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $45,254
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,235
Cost:
$1
$6,235 84,510 $6,235
84,510
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,458
Cost:
$56,350
$15,458 209,509 $15,458
209,509
kWh
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,260
Cost:
$4,050
$3,260 44,189 $3,260
44,189
kWh
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$45,254
Cost:
$2,500
$45,254 613,200 $45,254
613,200
kWh
05: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$4,339
Cost:
$8,740
$4,339 58,806 $4,339
58,806
kWh
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$339,042
Cost:
$1,340,000
$339,042 4,595,315 $339,042
4,595,315
kWh
TOTAL RECOMMENDED Savings:
$413,588
Cost:
$1,411,641
$413,588 5,605,530 $413,588
5,605,530
kWh
TOTAL IMPLEMENTED Savings:
$45,254
Cost:
$2,500
$45,254 613,200 $45,254
613,200
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage