IAC logo
IAC Assessment: GT0888
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0888
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2012
Principal Product Doors, Window, and Other
NAICS 331318 - Other Aluminum Rolling, Drawing, and Extruding
SIC 3354 - Aluminum Extruded Products
Sales $100,000,000-$500,000,000
# of Employees 345
Plant Area (Sq.Ft.) 900,000
Annual Production 10,000 Tons
Production Hrs. Annual 4,500
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,448,947 25,939,241 kWh $0.06
Electricity Demand $593,404 52,017 kW-months/year $11.41
Electricity Fees $450,705 - $ -
Natural Gas $776,819 104,582 MMBtu $7.43
TOTAL ENERGY COSTS $3,269,875
RECOMMENDED SAVINGS* $96,889 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$32,596
Cost:
-
$22,535 441,000 $10,061 882 - - - - $22,535
441,000
kWh
$10,061
882
kW-months/year
-
-
MMBtu
-
-
$
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$100
Cost:
-
$100 1,966 - - - - - - $100
1,966
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,563
Cost:
$2,250
$1,962 30,510 $601 61 - - - - $1,962
30,510
kWh
$601
61
kW-months/year
-
-
MMBtu
-
-
$
04: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$2,915
Cost:
$1,680
- - - - $2,915 406 - - -
-
kWh
-
-
kW-months/year
$2,915
406
MMBtu
-
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$17,200
Cost:
$15,000
- - - - $17,200 2,400 - - -
-
kWh
-
-
kW-months/year
$17,200
2,400
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$12,520
Cost:
$18,060
$12,520 245,029 - - - - - - $12,520
245,029
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$24,690
Cost:
$109,600
- - - - - - $24,690 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$24,690
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,305
Cost:
$18,600
$2,721 48,600 $1,584 144 - - - - $2,721
48,600
kWh
$1,584
144
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$96,889
Cost:
$165,190
$39,838 767,105 $12,246 1,087 $20,115 2,806 $24,690 - $39,838
767,105
kWh
$12,246
1,087
kW-months/year
$20,115
2,806
MMBtu
$24,690
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes