IAC logo
IAC Assessment: GT0931
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0931
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2019
Principal Product Carpet and Vinyl Flooring
NAICS 314110 - Carpet and Rug Mills
SIC 2273 - Carpets And Rugs
Sales $50,000,000-$100,000,000
# of Employees 264
Plant Area (Sq.Ft.) 154,900
Annual Production 17,918,625 Pieces
Production Hrs. Annual 6,240
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $169,907 3,264,000 kWh $0.05
Natural Gas $37,518 5,274 MMBtu $7.11
TOTAL ENERGY COSTS $207,425
RECOMMENDED SAVINGS* $110,485 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $35,746
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Electricity Usage Personnel Changes
$ kWh $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$12,292
Cost:
$3,500
$12,292 236,378 - - $12,292
236,378
kWh
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,451
Cost:
$1,382
$2,451 47,126 - - $2,451
47,126
kWh
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$19,194
Cost:
$25,005
$19,194 369,115 - - $19,194
369,115
kWh
-
-
$
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$7,893
Cost:
$19,194
$7,893 151,781 - - $7,893
151,781
kWh
-
-
$
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,664
Cost:
$4,500
$1,664 32,009 - - $1,664
32,009
kWh
-
-
$
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$14,047
Cost:
$39,068
$1,547 29,746 $12,500 - $1,547
29,746
kWh
$12,500
-
$
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$111
Cost:
$322
$111 2,131 - - $111
2,131
kWh
-
-
$
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$34
Cost:
$131
$34 660 - - $34
660
kWh
-
-
$
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$52,800
Cost:
$554,400
$52,800 1,015,399 - - $52,800
1,015,399
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$110,485
Cost:
$647,502
$97,985 1,884,345 $12,500 - $97,985
1,884,345
kWh
$12,500
-
$
TOTAL IMPLEMENTED Savings:
$35,746
Cost:
$34,840
$35,746 687,419 - - $35,746
687,419
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Personnel Changes Electricity Usage Personnel Changes