IAC logo
IAC Assessment: GT0942
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: GT0942
IAC Center Georgia Institute of Technology
Assessment Year 2020
Principal Product Cubed/Flaked Ice Making Machines
NAICS 333241 - Food Product Machinery Manufacturing
SIC 3569 - General Industrial Machinery, Nec
Sales $100,000,000-$500,000,000
# of Employees 523
Plant Area (Sq.Ft.) 220,000
Annual Production 78,000 Units
Production Hrs. Annual 4,680
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $675,857 7,719,000 kWh $0.09
Natural Gas $50,482 8,217 MMBtu $6.14
TOTAL ENERGY COSTS $726,339
RECOMMENDED SAVINGS* $331,826 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $35,845
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage
$ kWh $ MMBtu $ Tgal
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$20,227
Cost:
$1,450
$20,227 229,857 - - - - $20,227
229,857
kWh
-
-
MMBtu
-
-
Tgal
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$15,618
Cost:
$2,500
$15,618 177,478 - - - - $15,618
177,478
kWh
-
-
MMBtu
-
-
Tgal
03: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS Savings:
$14,945
Cost:
$4,781
$14,945 169,828 - - - - $14,945
169,828
kWh
-
-
MMBtu
-
-
Tgal
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$50,179
Cost:
$71,763
$50,179 570,220 - - - - $50,179
570,220
kWh
-
-
MMBtu
-
-
Tgal
05: 3.4151 MINIMIZE WATER USAGE Savings:
$3,202
Cost:
$5,700
$1,712 19,455 - - $1,490 156 $1,712
19,455
kWh
-
-
MMBtu
$1,490
156
Tgal
06: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$113,048
Cost:
$690,000
$164,736 1,872,000 $(-51,688) (-8,418) - - $164,736
1,872,000
kWh
$(-51,688)
(-8,418)
MMBtu
-
-
Tgal
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$114,607
Cost:
$699,103
$114,607 1,308,931 - - - - $114,607
1,308,931
kWh
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$331,826
Cost:
$1,475,297
$382,025 4,347,768 $(-51,688) (-8,418) $1,490 156 $382,025
4,347,768
kWh
$(-51,688)
(-8,418)
MMBtu
$1,490
156
Tgal
TOTAL IMPLEMENTED Savings:
$35,845
Cost:
$3,950
$35,845 407,335 - - - - $35,845
407,335
kWh
-
-
MMBtu
-
-
Tgal
Savings
Cost
$ kWh $ MMBtu $ Tgal
Electricity Usage Natural Gas Water Usage Electricity Usage Natural Gas Water Usage