Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2020
Principal Product Rubber Seals and Components
NAICS 326220 - Rubber and Plastics Hoses and Belting Manufacturing
SIC 3052 - Rubber & Plastics Hose & Belting
Sales $50,000,000-$100,000,000
# of Employees 400
Plant Area (Sq.Ft.) 155,285
Annual Production 794,836,918 Pieces
Production Hrs. Annual 6,900
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,060,030 16,810,924 kWh $0.06
TOTAL ENERGY COSTS $1,060,030
RECOMMENDED SAVINGS* $154,699 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $55,043
#|Description Savings
Cost
Status Electricity Usage Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Fees One-time Revenue or Avoided Cost
$ kWh $ $ $ $
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,607
Cost:
$225
$1,607 25,503 - - - - $1,607
25,503
kWh
-
-
$
-
-
$
02: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$1,114
Cost:
$400
$1,114 17,687 - - - - $1,114
17,687
kWh
-
-
$
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,557
Cost:
$4,500
$8,057 127,890 - - $(-2,500) - $8,057
127,890
kWh
-
-
$
$(-2,500)
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$43,586
Cost:
$47,656
$43,586 691,835 - - - - $43,586
691,835
kWh
-
-
$
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$337
Cost:
$401
$337 5,354 - - - - $337
5,354
kWh
-
-
$
-
-
$
06: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$1,358
Cost:
$5,106
- - $1,358 - - - -
-
kWh
$1,358
-
$
-
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$97,184
Cost:
$1,413,929
$97,184 1,541,232 - - - - $97,184
1,541,232
kWh
-
-
$
-
-
$
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$3,956
Cost:
$38,500
$3,956 62,795 - - - - $3,956
62,795
kWh
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$154,699
Cost:
$1,510,717
$155,841 2,472,296 $1,358 - $(-2,500) - $155,841
2,472,296
kWh
$1,358
-
$
$(-2,500)
-
$
TOTAL IMPLEMENTED Savings:
$55,043
Cost:
$91,282
$57,543 913,377 - - $(-2,500) - $57,543
913,377
kWh
-
-
$
$(-2,500)
-
$
Savings
Cost
$ kWh $ $ $ $
Electricity Usage Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Fees One-time Revenue or Avoided Cost