Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2020
Principal Product Custom Metal Powder Coated Products
NAICS 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479 - Metal Coating And Allied Services
Sales $10,000,000-$50,000,000
# of Employees 85
Plant Area (Sq.Ft.) 50,000
Annual Production 6,060,000 Pieces
Production Hrs. Annual 6,240
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $139,171 1,434,720 kWh $0.10
Natural Gas $144,560 45,399 MMBtu $3.18
TOTAL ENERGY COSTS $283,731
RECOMMENDED SAVINGS* $41,560 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,318
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Electricity Usage Personnel Changes
$ kWh $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,577
Cost:
$1,850
$8,477 87,394 $(-2,900) - $8,477
87,394
kWh
$(-2,900)
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,031
Cost:
$400
$1,031 10,630 - - $1,031
10,630
kWh
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,911
Cost:
$2,747
$4,911 50,633 - - $4,911
50,633
kWh
-
-
$
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$326
Cost:
$225
$326 3,364 - - $326
3,364
kWh
-
-
$
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$7,985
Cost:
$8,432
$7,985 82,322 - - $7,985
82,322
kWh
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$472
Cost:
$1,123
$472 4,864 - - $472
4,864
kWh
-
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,866
Cost:
$5,680
$1,866 19,234 - - $1,866
19,234
kWh
-
-
$
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$19,391
Cost:
$226,091
$19,391 199,899 - - $19,391
199,899
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$41,560
Cost:
$246,548
$44,460 458,341 $(-2,900) - $44,460
458,341
kWh
$(-2,900)
-
$
TOTAL IMPLEMENTED Savings:
$12,318
Cost:
$6,345
$15,218 156,886 $(-2,900) - $15,218
156,886
kWh
$(-2,900)
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Personnel Changes Electricity Usage Personnel Changes