Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Styrofoam Cups |
NAICS | n/a |
SIC | 3086 - Plastics Foam Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 83,000 |
Annual Production | 8,300,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | NJ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $804,078 | 11,009,965 | kWh | $0.07 |
Electricity Demand | $170,194 | 17,764 | kW-months/year | $9.58 |
Electricity Fees | $7,932 | - | $ | - |
Natural Gas | $848,546 | 273,845 | MMBtu | $3.10 |
TOTAL ENERGY COSTS | $1,830,750 | |||
RECOMMENDED SAVINGS* | $750,320 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $205,873 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20,898 Cost: $27,392 |
$17,670 | 241,794 | $3,228 | 337 | - | - | - | - | - | - | - | - | - | - |
$17,670 241,794 kWh |
$3,228 337 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $20,894 Cost: $19,210 |
$17,670 | 241,794 | $3,224 | 336 | - | - | - | - | - | - | - | - | - | - |
$17,670 241,794 kWh |
$3,224 336 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $179,887 Cost: $800,000 |
$513,959 | 7,032,825 | $94,238 | 9,847 | $(-334,062) | (-80,111) | - | - | $(-94,248) | - | - | - | - | - |
$513,959 7,032,825 kWh |
$94,238 9,847 kW-months/year |
$(-334,062) (-80,111) MMBtu |
- - Tgal |
$(-94,248) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $18,091 Cost: $22,000 |
$15,335 | 209,848 | $2,756 | 288 | - | - | - | - | - | - | - | - | - | - |
$15,335 209,848 kWh |
$2,756 288 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $35,718 Cost: $5,590 |
$30,206 | 413,247 | $5,512 | 576 | - | - | - | - | - | - | - | - | - | - |
$30,206 413,247 kWh |
$5,512 576 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.321 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES |
Savings: $196,000 Cost: $50,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $196,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
$196,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $19,642 Cost: $14,400 |
$15,108 | 206,917 | $2,834 | 295 | - | - | - | - | $1,700 | - | - | - | - | - |
$15,108 206,917 kWh |
$2,834 295 kW-months/year |
- - MMBtu |
- - Tgal |
$1,700 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $507 Cost: $930 |
- | - | - | - | - | - | $507 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$507 - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $63,000 Cost: $56,700 |
- | - | - | - | - | - | - | - | - | - | - | - | $63,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
$63,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $130,320 Cost: $186,569 |
- | - | - | - | - | - | - | - | $49,920 | - | - | - | $80,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$49,920 - $ |
- - $ |
$80,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $65,363 Cost: $26,200 |
- | - | - | - | - | - | - | - | - | - | $65,363 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$65,363 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $750,320 Cost: $1,208,991 |
$609,948 | 8,346,425 | $111,792 | 11,679 | $(-334,062) | (-80,111) | $507 | - | $(-42,628) | - | $65,363 | - | $339,400 | - | $609,948 8,346,425 kWh |
$111,792 11,679 kW-months/year |
$(-334,062) (-80,111) MMBtu |
$507 - Tgal |
$(-42,628) - $ |
$65,363 - $ |
$339,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $205,873 Cost: $135,092 |
$65,546 | 896,835 | $11,964 | 1,249 | - | - | - | - | - | - | $65,363 | - | $63,000 | - | $65,546 896,835 kWh |
$11,964 1,249 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$65,363 - $ |
$63,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Primary Product |