Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Expanding File Folders |
NAICS | n/a |
SIC | 2677 - Envelopes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 68,000 |
Annual Production | 2,080,000 Pounds |
Production Hrs. Annual | 2,132 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $41,674 | 690,504 | kWh | $0.06 |
Electricity Demand | $105,435 | 3,653 | kW-months/year | $28.86 |
Electricity Fees | $7,665 | - | $ | - |
Natural Gas | $7,134 | 875 | MMBtu | $8.15 |
TOTAL ENERGY COSTS | $183,908 | |||
RECOMMENDED SAVINGS* | $40,663 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,550 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,148 Cost: $31,658 |
$3,448 | 57,151 | $9,700 | 324 | - | - | - | - | - | - |
$3,448 57,151 kWh |
$9,700 324 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $791 Cost: $700 |
$214 | 3,517 | $577 | 20 | - | - | - | - | - | - |
$214 3,517 kWh |
$577 20 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $413 Cost: $310 |
$246 | 4,103 | $167 | 6 | - | - | - | - | - | - |
$246 4,103 kWh |
$167 6 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,566 Cost: $60 |
$1,204 | 19,930 | $3,362 | 112 | - | - | - | - | - | - |
$1,204 19,930 kWh |
$3,362 112 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $9,000 Cost: $6,500 |
- | - | - | - | - | - | - | - | $9,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$9,000 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING |
Savings: $5,161 Cost: $7,590 |
$4,520 | 75,029 | $641 | 21 | - | - | - | - | - | - |
$4,520 75,029 kWh |
$641 21 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,238 Cost: $20,020 |
$2,285 | 37,515 | $3,953 | 173 | - | - | - | - | - | - |
$2,285 37,515 kWh |
$3,953 173 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $956 Cost: $3,000 |
- | - | - | - | $956 | 123 | - | - | - | - |
- - kWh |
- - kW-months/year |
$956 123 MMBtu |
- - Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4151 MINIMIZE WATER USAGE |
Savings: $390 Cost: $100 |
- | - | - | - | - | - | $390 | 120,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$390 120,000 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,663 Cost: $69,938 |
$11,917 | 197,245 | $18,400 | 656 | $956 | 123 | $390 | 120,000 | $9,000 | - | $11,917 197,245 kWh |
$18,400 656 kW-months/year |
$956 123 MMBtu |
$390 120,000 Tgal |
$9,000 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,550 Cost: $4,110 |
$460 | 7,620 | $744 | 26 | $956 | 123 | $390 | 120,000 | - | - | $460 7,620 kWh |
$744 26 kW-months/year |
$956 123 MMBtu |
$390 120,000 Tgal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) |