IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Thermoformed plastic packaging |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 1,000,000 Pounds |
Production Hrs. Annual | 3,000 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $60,877 | 1,057,151 | kWh | $0.06 |
Electricity Demand | $140,545 | 6,032 | kW-months/year | $23.30 |
Electricity Fees | $9,168 | - | $ | - |
Natural Gas | $211 | 11 | MMBtu | $19.18 |
Fuel Oil #2 | $24,096 | 3,988 | MMBtu | $6.04 |
TOTAL ENERGY COSTS | $234,897 | |||
RECOMMENDED SAVINGS* | $35,959 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,639 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,263 Cost: $16,755 |
$1,479 | 24,326 | $2,784 | 120 | - | - |
$1,479 24,326 kWh |
$2,784 120 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,201 Cost: $168 |
$937 | 16,413 | $2,264 | 98 | - | - |
$937 16,413 kWh |
$2,264 98 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $320 Cost: $500 |
$320 | 5,569 | - | - | - | - |
$320 5,569 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $800 Cost: $300 |
$800 | 13,775 | - | - | - | - |
$800 13,775 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.4310 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $9,375 Cost: - |
- | - | - | - | $9,375 | - |
- - kWh |
- - kW-months/year |
$9,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.5210 CLEAR AND RENT EXISTING SPACE |
Savings: $18,000 Cost: $3,000 |
- | - | - | - | $18,000 | - |
- - kWh |
- - kW-months/year |
$18,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,959 Cost: $20,723 |
$3,536 | 60,083 | $5,048 | 218 | $27,375 | - | $3,536 60,083 kWh |
$5,048 218 kW-months/year |
$27,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,639 Cost: $20,223 |
$3,216 | 54,514 | $5,048 | 218 | $27,375 | - | $3,216 54,514 kWh |
$5,048 218 kW-months/year |
$27,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost |