Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Boilers & Tanks |
NAICS | n/a |
SIC | 3433 - Heating Equipment, Except Electric |
Sales | $10,000,000-$50,000,000 |
# of Employees | 275 |
Plant Area (Sq.Ft.) | 27,000 |
Annual Production | 550 Pieces |
Production Hrs. Annual | 4,130 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $28,391 | 530,774 | kWh | $0.05 |
Electricity Demand | $43,079 | 2,031 | kW-months/year | $21.21 |
Natural Gas | $5,277 | 565 | MMBtu | $9.34 |
TOTAL ENERGY COSTS | $76,747 | |||
RECOMMENDED SAVINGS* | $29,980 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,496 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,672 Cost: $9,033 |
$2,119 | 39,566 | $2,553 | 120 | - | - | - | - | - | - |
$2,119 39,566 kWh |
$2,553 120 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,258 Cost: $150 |
$2,452 | 46,014 | $2,806 | 132 | - | - | - | - | - | - |
$2,452 46,014 kWh |
$2,806 132 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $2,914 Cost: - |
- | - | - | - | $2,914 | 312 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,914 312 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $960 Cost: $3,000 |
- | - | - | - | - | - | - | - | $960 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$960 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $2,496 Cost: $5,000 |
- | - | - | - | - | - | $2,496 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,496 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $6,240 Cost: $340 |
- | - | - | - | - | - | - | - | $6,240 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$6,240 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $6,192 Cost: $5,000 |
- | - | - | - | - | - | - | - | $6,192 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$6,192 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $1,248 Cost: $2,500 |
- | - | - | - | - | - | - | - | $1,248 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,248 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,980 Cost: $25,023 |
$4,571 | 85,580 | $5,359 | 252 | $2,914 | 312 | $2,496 | - | $14,640 | - | $4,571 85,580 kWh |
$5,359 252 kW-months/year |
$2,914 312 MMBtu |
$2,496 - $ |
$14,640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,496 Cost: $5,000 |
- | - | - | - | - | - | $2,496 | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
$2,496 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |