Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Milk |
NAICS | n/a |
SIC | 2026 - Fluid Milk |
Sales | $50,000,000-$100,000,000 |
# of Employees | 190 |
Plant Area (Sq.Ft.) | 653,000 |
Annual Production | 41,000 Thousand Gallons |
Production Hrs. Annual | 8,736 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $140,330 | 3,644,490 | kWh | $0.04 |
Electricity Demand | $182,465 | 15,658 | kW-months/year | $11.65 |
Electricity Fees | $28,681 | - | $ | - |
Natural Gas | $659,008 | 109,103 | MMBtu | $6.04 |
TOTAL ENERGY COSTS | $1,010,484 | |||
RECOMMENDED SAVINGS* | $188,415 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $55,549 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,960 Cost: $11,729 |
$4,113 | 106,975 | $1,847 | 159 | - | - | - | - |
$4,113 106,975 kWh |
$1,847 159 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $7,410 Cost: $15 |
$5,233 | 135,991 | $2,177 | 187 | - | - | - | - |
$5,233 135,991 kWh |
$2,177 187 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,255 Cost: $600 |
$4,255 | 110,492 | - | - | - | - | - | - |
$4,255 110,492 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $12,126 Cost: $5,000 |
$8,570 | 222,743 | $3,556 | 306 | - | - | - | - |
$8,570 222,743 kWh |
$3,556 306 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS |
Savings: $34,444 Cost: $20,000 |
- | - | - | - | - | - | $34,444 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$34,444 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8112 COMBINE UTILITY METERS |
Savings: $4,142 Cost: $6,000 |
- | - | $4,142 | 356 | - | - | - | - |
- - kWh |
$4,142 356 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $115,354 Cost: $4,000 |
- | - | - | - | - | - | $115,354 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$115,354 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $4,200 Cost: $375 |
- | - | - | - | - | - | $4,200 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$4,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $524 Cost: $2,500 |
- | - | - | - | $524 | 131,040 | - | - |
- - kWh |
- - kW-months/year |
$524 131,040 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $188,415 Cost: $50,219 |
$22,171 | 576,201 | $11,722 | 1,008 | $524 | 131,040 | $153,998 | - | $22,171 576,201 kWh |
$11,722 1,008 kW-months/year |
$524 131,040 Tgal |
$153,998 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $55,549 Cost: $28,475 |
$12,825 | 333,235 | $3,556 | 306 | $524 | 131,040 | $38,644 | - | $12,825 333,235 kWh |
$3,556 306 kW-months/year |
$524 131,040 Tgal |
$38,644 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost |