Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Iowa State University
Assessment Year 1995
Principal Product athletic jackets and hats
NAICS n/a
SIC 2353 - Hats, Caps, And Millinery
Sales $50,000,000-$100,000,000
# of Employees 677
Plant Area (Sq.Ft.) 450,000
Annual Production 12,000,000 Pieces
Production Hrs. Annual 3,680
Location (State) IA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $400,128 7,427,315 kWh $0.05
Natural Gas $36,873 9,501 MMBtu $3.88
TOTAL ENERGY COSTS $437,001
RECOMMENDED SAVINGS* $32,600 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $23,002
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$17,919
Cost:
-
$14,111 262,016 $3,808 981 $14,111
262,016
kWh
$3,808
981
MMBtu
02: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$8,223
Cost:
$8,195
$8,223 152,696 - - $8,223
152,696
kWh
-
-
MMBtu
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,759
Cost:
$405
$1,759 32,532 - - $1,759
32,532
kWh
-
-
MMBtu
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,119
Cost:
$1,686
$1,119 20,809 - - $1,119
20,809
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,982
Cost:
$1,090
$1,982 36,928 - - $1,982
36,928
kWh
-
-
MMBtu
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$894
Cost:
$1,050
$1,085 20,223 $(-191) (-49) $1,085
20,223
kWh
$(-191)
(-49)
MMBtu
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$367
Cost:
$194
- - $367 95 -
-
kWh
$367
95
MMBtu
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$223
Cost:
$25
$223 4,103 - - $223
4,103
kWh
-
-
MMBtu
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$114
Cost:
$105
$114 2,052 - - $114
2,052
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$32,600
Cost:
$12,750
$28,616 531,359 $3,984 1,027 $28,616
531,359
kWh
$3,984
1,027
MMBtu
TOTAL IMPLEMENTED Savings:
$23,002
Cost:
$3,206
$19,194 356,388 $3,808 981 $19,194
356,388
kWh
$3,808
981
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas