Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 1998 |
Principal Product | doors & work surfaces |
NAICS | n/a |
SIC | 2431 - Millwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 220,000 |
Annual Production | 1,600,000 Pieces |
Production Hrs. Annual | 6,732 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $268,428 | 8,332,063 | kWh | $0.03 |
Electricity Demand | $68,642 | 20,460 | kW-months/year | $3.35 |
Natural Gas | $28,464 | 6,420 | MMBtu | $4.43 |
TOTAL ENERGY COSTS | $434,352 | |||
RECOMMENDED SAVINGS* | $15,727 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,717 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4311 RECOVER MECHANICAL ENERGY |
Savings: $3,725 Cost: $4,986 |
$2,325 | 105,803 | $1,400 | 188 | - | - | - | - |
$2,325 105,803 kWh |
$1,400 188 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $2,195 Cost: $500 |
- | - | - | - | $6,660 | 4,950 | $(-4,465) | - |
- - kWh |
- - kW-months/year |
$6,660 4,950 lb |
$(-4,465) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,275 Cost: $4,000 |
$2,044 | 92,907 | $1,231 | 166 | - | - | - | - |
$2,044 92,907 kWh |
$1,231 166 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,178 Cost: $4,966 |
$2,608 | 118,699 | $1,570 | 211 | - | - | - | - |
$2,608 118,699 kWh |
$1,570 211 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,344 Cost: $400 |
$832 | 41,032 | $512 | 73 | - | - | - | - |
$832 41,032 kWh |
$512 73 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,010 Cost: $3,458 |
$1,010 | 46,014 | - | - | - | - | - | - |
$1,010 46,014 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $15,727 Cost: $18,310 |
$8,819 | 404,455 | $4,713 | 638 | $6,660 | 4,950 | $(-4,465) | - | $8,819 404,455 kWh |
$4,713 638 kW-months/year |
$6,660 4,950 lb |
$(-4,465) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,717 Cost: $14,852 |
$7,809 | 358,441 | $4,713 | 638 | $6,660 | 4,950 | $(-4,465) | - | $7,809 358,441 kWh |
$4,713 638 kW-months/year |
$6,660 4,950 lb |
$(-4,465) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (haz) | Primary Raw Material |