Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 1999 |
Principal Product | wood doors and cabinetry |
NAICS | n/a |
SIC | 2431 - Millwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 180,000 |
Annual Production | 72,800 Pieces |
Production Hrs. Annual | 2,210 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $89,069 | 3,304,514 | kWh | $0.03 |
Electricity Demand | $71,745 | 10,116 | kW-months/year | $7.09 |
Natural Gas | $49,297 | 8,829 | MMBtu | $5.58 |
TOTAL ENERGY COSTS | $254,111 | |||
RECOMMENDED SAVINGS* | $43,755 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,780 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1224 REPLACE BOILER |
Savings: $22,643 Cost: $12,000 |
- | - | - | - | $22,643 | 4,147 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$22,643 4,147 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,292 Cost: $2,306 |
$596 | 22,274 | $696 | 98 | - | - | - | - | - | - | - | - | - | - |
$596 22,274 kWh |
$696 98 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,488 Cost: $231 |
$647 | 24,033 | $841 | 119 | - | - | - | - | - | - | - | - | - | - |
$647 24,033 kWh |
$841 119 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $370 Cost: $1,417 |
$158 | 5,862 | $212 | 30 | - | - | - | - | - | - | - | - | - | - |
$158 5,862 kWh |
$212 30 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $337 Cost: $1,530 |
$337 | 12,603 | - | - | - | - | - | - | - | - | - | - | - | - |
$337 12,603 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $11,418 Cost: $7,660 |
- | - | - | - | - | - | - | - | $6,732 | 306,000 | $(-1,434) | - | $6,120 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$6,732 306,000 lb |
$(-1,434) - $ |
$6,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.3113 USE OTHER METHODS FOR NEUTRALIZATION |
Savings: $6,207 Cost: $100 |
- | - | - | - | - | - | $11,000 | 4,092 | $(-4,793) | 19,500 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,000 4,092 gal |
$(-4,793) 19,500 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,755 Cost: $25,244 |
$1,738 | 64,772 | $1,749 | 247 | $22,643 | 4,147 | $11,000 | 4,092 | $1,939 | 325,500 | $(-1,434) | - | $6,120 | - | $1,738 64,772 kWh |
$1,749 247 kW-months/year |
$22,643 4,147 MMBtu |
$11,000 4,092 gal |
$1,939 325,500 lb |
$(-1,434) - $ |
$6,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,780 Cost: $2,537 |
$1,243 | 46,307 | $1,537 | 217 | - | - | - | - | - | - | - | - | - | - | $1,243 46,307 kWh |
$1,537 217 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | By-product Production |