Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2000 |
Principal Product | refrigerated displays |
NAICS | n/a |
SIC | 3589 - Service Industry Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 6,500 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $59,182 | 1,631,008 | kWh | $0.04 |
Electricity Demand | $37,154 | 4,584 | kW-months/year | $8.11 |
Natural Gas | $21,690 | 4,302 | MMBtu | $5.04 |
TOTAL ENERGY COSTS | $119,732 | |||
RECOMMENDED SAVINGS* | $133,197 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,078 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $23,446 Cost: $45,125 |
$13,005 | 358,148 | $10,441 | 1,289 | - | - | - | - | - | - | - | - |
$13,005 358,148 kWh |
$10,441 1,289 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,870 Cost: $753 |
$1,866 | 51,290 | $1,004 | 124 | - | - | - | - | - | - | - | - |
$1,866 51,290 kWh |
$1,004 124 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $986 Cost: $40 |
$756 | 20,223 | $230 | 29 | - | - | - | - | - | - | - | - |
$756 20,223 kWh |
$230 29 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $288 Cost: $25 |
$223 | 6,155 | $65 | 8 | - | - | - | - | - | - | - | - |
$223 6,155 kWh |
$65 8 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,920 Cost: $1,206 |
- | - | - | - | $1,920 | 393 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,920 393 MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $47,250 Cost: $7,175 |
- | - | - | - | - | - | - | - | $47,250 | 2,250 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$47,250 2,250 gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8211 CONVERT TO AQUEOUS CLEANING SYSTEM |
Savings: $56,437 Cost: $420 |
- | - | - | - | - | - | $(-5) | (-16,250) | $56,453 | 9,750 | $(-11) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-5) (-16,250) Tgal |
$56,453 9,750 gal |
$(-11) - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,197 Cost: $54,744 |
$15,850 | 435,816 | $11,740 | 1,450 | $1,920 | 393 | $(-5) | (-16,250) | $103,703 | 12,000 | $(-11) | - | $15,850 435,816 kWh |
$11,740 1,450 kW-months/year |
$1,920 393 MMBtu |
$(-5) (-16,250) Tgal |
$103,703 12,000 gal |
$(-11) - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,078 Cost: $1,984 |
$2,089 | 57,445 | $1,069 | 132 | $1,920 | 393 | - | - | - | - | - | - | $2,089 57,445 kWh |
$1,069 132 kW-months/year |
$1,920 393 MMBtu |
- - Tgal |
- - gal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (non-haz) | Water Consumption |