Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2002 |
Principal Product | Hydrants, valves, pumps |
NAICS | n/a |
SIC | 3494 - Valves And Pipe Fittings, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 370 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 211,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $125,955 | 3,661,840 | kWh | $0.03 |
Electricity Demand | $63,315 | 8,412 | kW-months/year | $7.53 |
Natural Gas | $97,412 | 9,901 | MMBtu | $9.84 |
TOTAL ENERGY COSTS | $403,654 | |||
RECOMMENDED SAVINGS* | $108,276 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $107,021 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,274 Cost: $458 |
$1,990 | 68,134 | $1,284 | 131 | - | - |
$1,990 68,134 kWh |
$1,284 131 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $806 Cost: $237 |
$489 | 16,745 | $317 | 32 | - | - |
$489 16,745 kWh |
$317 32 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $449 Cost: $92 |
$273 | 9,360 | $176 | 18 | - | - |
$273 9,360 kWh |
$176 18 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $39,507 Cost: $800 |
- | - | $39,507 | 4,032 | - | - |
- - kWh |
$39,507 4,032 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $46,580 Cost: $320 |
- | - | - | - | $46,580 | - |
- - kWh |
- - kW-months/year |
$46,580 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT |
Savings: $12,642 Cost: $3,424 |
- | - | - | - | $12,642 | - |
- - kWh |
- - kW-months/year |
$12,642 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,018 Cost: $7,500 |
- | - | - | - | $5,018 | - |
- - kWh |
- - kW-months/year |
$5,018 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,276 Cost: $12,831 |
$2,752 | 94,239 | $41,284 | 4,213 | $64,240 | - | $2,752 94,239 kWh |
$41,284 4,213 kW-months/year |
$64,240 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $107,021 Cost: $12,502 |
$1,990 | 68,134 | $40,791 | 4,163 | $64,240 | - | $1,990 68,134 kWh |
$40,791 4,163 kW-months/year |
$64,240 - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) |