Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2005 |
Principal Product | Glass vials |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 46,000 |
Annual Production | 134,400,000 Pieces |
Production Hrs. Annual | 8,064 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $73,310 | 3,040,848 | kWh | $0.02 |
Electricity Demand | $35,589 | 5,004 | kW-months/year | $7.11 |
Natural Gas | $306,657 | 39,782 | MMBtu | $7.71 |
TOTAL ENERGY COSTS | $415,556 | |||
RECOMMENDED SAVINGS* | $1,038,362 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,025,719 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,317 Cost: $50 |
$1,051 | 43,626 | $266 | 65 | - | - | - | - | - | - | - | - |
$1,051 43,626 kWh |
$266 65 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $779 Cost: $19 |
$622 | 25,805 | $157 | 38 | - | - | - | - | - | - | - | - |
$622 25,805 kWh |
$157 38 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,995 Cost: $3,000 |
$1,592 | 66,043 | $403 | 98 | - | - | - | - | - | - | - | - |
$1,592 66,043 kWh |
$403 98 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,148 Cost: $1,001 |
$1,148 | 47,639 | - | - | - | - | - | - | - | - | - | - |
$1,148 47,639 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $628 Cost: $1,600 |
- | - | - | - | $628 | 109 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$628 109 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $1,000,000 Cost: $152,672 |
- | - | - | - | - | - | - | - | - | - | $1,000,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$1,000,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $11,495 Cost: $14,000 |
- | - | - | - | - | - | $11,495 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,495 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.624 HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME |
Savings: $21,000 Cost: $7,216 |
- | - | - | - | - | - | - | - | $21,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$21,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,038,362 Cost: $179,558 |
$4,413 | 183,113 | $826 | 202 | $628 | 109 | $11,495 | - | $21,000 | - | $1,000,000 | - | $4,413 183,113 kWh |
$826 202 kW-months/year |
$628 109 MMBtu |
$11,495 - $ |
$21,000 - $ |
$1,000,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,025,719 Cost: $164,557 |
$3,265 | 135,474 | $826 | 202 | $628 | 109 | - | - | $21,000 | - | $1,000,000 | - | $3,265 135,474 kWh |
$826 202 kW-months/year |
$628 109 MMBtu |
- - $ |
$21,000 - $ |
$1,000,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product |