Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2006 |
Principal Product | Primal Beef Cuts |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | >$500,000,000 |
# of Employees | 1,800 |
Plant Area (Sq.Ft.) | 520,000 |
Annual Production | 1,200,000 Units |
Production Hrs. Annual | 5,616 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,670,511 | 85,806,954 | kWh | $0.02 |
Electricity Demand | $1,702,184 | 162,588 | kW-months/year | $10.47 |
Electricity Fees | $3,372,996 | - | $ | - |
Natural Gas | $5,048,817 | 571,047 | MMBtu | $8.84 |
TOTAL ENERGY COSTS | $11,794,508 | |||
RECOMMENDED SAVINGS* | $192,371 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,016 Cost: $4,118 |
$2,380 | 123,982 | $2,636 | 253 | - | - |
$2,380 123,982 kWh |
$2,636 253 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,968 Cost: $71,321 |
$7,048 | 368,962 | $5,920 | 568 | - | - |
$7,048 368,962 kWh |
$5,920 568 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,397 Cost: $385 |
$1,397 | 72,764 | - | - | - | - |
$1,397 72,764 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $7,603 Cost: $1,108 |
$3,497 | 184,211 | $4,106 | 408 | - | - |
$3,497 184,211 kWh |
$4,106 408 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,632 Cost: $60 |
$1,219 | 63,461 | $1,413 | 136 | - | - |
$1,219 63,461 kWh |
$1,413 136 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,105 Cost: $3,000 |
$5,143 | 267,883 | $5,962 | 572 | - | - |
$5,143 267,883 kWh |
$5,962 572 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,904 Cost: $140 |
$882 | 45,938 | $1,022 | 98 | - | - |
$882 45,938 kWh |
$1,022 98 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $6,601 Cost: $1,302 |
- | - | - | - | $6,601 | 747 |
- - kWh |
- - kW-months/year |
$6,601 747 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $45,154 Cost: $2,500 |
- | - | - | - | $45,154 | 5,108 |
- - kWh |
- - kW-months/year |
$45,154 5,108 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2162 REDUCE EXCESS STEAM BLEEDING |
Savings: $97,991 Cost: $10,000 |
- | - | - | - | $97,991 | 11,085 |
- - kWh |
- - kW-months/year |
$97,991 11,085 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $192,371 Cost: $93,934 |
$21,566 | 1,127,201 | $21,059 | 2,035 | $149,746 | 16,940 | $21,566 1,127,201 kWh |
$21,059 2,035 kW-months/year |
$149,746 16,940 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |