Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Iowa State University |
---|---|
Assessment Year | 2007 |
Principal Product | Data Storage Devices |
NAICS | 334112 - Computer Storage Device Manufacturing |
SIC | 3572 - Computer Storage Devices |
Sales | >$500,000,000 |
# of Employees | 390 |
Plant Area (Sq.Ft.) | 368,000 |
Annual Production | 2,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | ND |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,975,606 | 45,682,560 | kWh | $0.04 |
Electricity Demand | $495,770 | 72,636 | kW-months/year | $6.83 |
Natural Gas | $354,793 | 52,200 | MMBtu | $6.80 |
TOTAL ENERGY COSTS | $2,826,169 | |||
RECOMMENDED SAVINGS* | $72,945 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $36,598 Cost: $46,276 |
$30,058 | 697,394 | $6,540 | 958 |
$30,058 697,394 kWh |
$6,540 958 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,956 Cost: $13,071 |
$3,171 | 73,574 | $785 | 120 |
$3,171 73,574 kWh |
$785 120 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,650 Cost: $1,078 |
$1,650 | 38,263 | - | - |
$1,650 38,263 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $7,664 Cost: $1,875 |
$7,664 | 177,793 | - | - |
$7,664 177,793 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,033 Cost: $3,978 |
$2,033 | 47,174 | - | - |
$2,033 47,174 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $21,044 Cost: $2,000 |
$17,282 | 400,982 | $3,762 | 551 |
$17,282 400,982 kWh |
$3,762 551 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $72,945 Cost: $68,278 |
$61,858 | 1,435,180 | $11,087 | 1,629 | $61,858 1,435,180 kWh |
$11,087 1,629 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - - kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |