IAC logo
IAC Assessment: IC0038
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0038
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2002
Principal Product Pneumatic Valves and Cylinders
NAICS n/a
SIC 3492 - Fluid Power Valves & Hose Fittings
Sales $5,000,000-$10,000,000
# of Employees 55
Plant Area (Sq.Ft.) 31,000
Annual Production 1,000,000 Pieces
Production Hrs. Annual 3,443
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $33,225 594,236 kWh $0.06
Electricity Demand $23,916 2,150 kW-months/year $11.12
Electricity Fees $22,302 - $ -
Natural Gas $30,284 3,168 MMBtu $9.56
TOTAL ENERGY COSTS $102,420
RECOMMENDED SAVINGS* $27,169 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,057
Cost:
$2,300
$1,037 26,611 $1,020 93 - - - - - - - - $1,037
26,611
kWh
$1,020
93
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,313
Cost:
$13,137
$841 21,558 $826 75 - - $215 - - - $431 - $841
21,558
kWh
$826
75
kW-months/year
-
-
MMBtu
$215
-
$
-
-
$
$431
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$487
Cost:
$2,536
$171 4,399 $246 22 - - $35 - - - $35 - $171
4,399
kWh
$246
22
kW-months/year
-
-
MMBtu
$35
-
$
-
-
$
$35
-
$
04: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$2,392
Cost:
$27,900
- - - - $2,392 250 - - - - - - -
-
kWh
-
-
kW-months/year
$2,392
250
MMBtu
-
-
$
-
-
$
-
-
$
05: 4.4470 AUTOMATE PAYROLL SYSTEM Savings:
$19,920
Cost:
$8,340
- - - - - - $4,870 - $15,050 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,870
-
$
$15,050
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$27,169
Cost:
$54,213
$2,049 52,568 $2,092 190 $2,392 250 $5,120 - $15,050 - $466 - $2,049
52,568
kWh
$2,092
190
kW-months/year
$2,392
250
MMBtu
$5,120
-
$
$15,050
-
$
$466
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost