Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2004 |
Principal Product | Ground Beef, Bread, Sauces |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | $10,000,000-$50,000,000 |
# of Employees | 179 |
Plant Area (Sq.Ft.) | 164,250 |
Annual Production | 40,375,000 Pounds |
Production Hrs. Annual | 2,496 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $207,097 | 6,421,599 | kWh | $0.03 |
Electricity Demand | $178,742 | 13,670 | kW-months/year | $13.08 |
Electricity Fees | $29,531 | - | $ | - |
Natural Gas | $181,796 | 35,663 | MMBtu | $5.10 |
TOTAL ENERGY COSTS | $597,166 | |||
RECOMMENDED SAVINGS* | $55,097 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5111 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS |
Savings: $30,046 Cost: $118,316 |
- | - | - | - | $30,046 | 5,903 | - | - | - | - |
- - kWh |
- - kW-months/year |
$30,046 5,903 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,893 Cost: $6,541 |
- | - | - | - | $1,893 | 372 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,893 372 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,003 Cost: $398 |
- | - | - | - | $1,003 | 197 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,003 197 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,385 Cost: $2,462 |
$1,385 | 38,458 | - | - | - | - | - | - | - | - |
$1,385 38,458 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,433 Cost: $1,100 |
$1,433 | 39,848 | $1,000 | 77 | - | - | - | - | - | - |
$1,433 39,848 kWh |
$1,000 77 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,391 Cost: $850 |
$1,391 | 38,635 | - | - | - | - | - | - | - | - |
$1,391 38,635 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,546 Cost: $4,320 |
$467 | 12,982 | $233 | 18 | - | - | $528 | - | $318 | - |
$467 12,982 kWh |
$233 18 kW-months/year |
- - MMBtu |
$528 - $ |
$318 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,965 Cost: $40,012 |
$2,379 | 68,131 | $3,110 | 238 | - | - | $727 | - | $749 | - |
$2,379 68,131 kWh |
$3,110 238 kW-months/year |
- - MMBtu |
$727 - $ |
$749 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,235 Cost: $14,043 |
$1,759 | 49,038 | $476 | 37 | - | - | - | - | - | - |
$1,759 49,038 kWh |
$476 37 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,554 Cost: $29,500 |
$3,305 | 91,813 | $2,872 | 220 | - | - | $(-424) | - | $(-199) | - |
$3,305 91,813 kWh |
$2,872 220 kW-months/year |
- - MMBtu |
$(-424) - $ |
$(-199) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $646 Cost: - |
$409 | 11,370 | $237 | 18 | - | - | - | - | - | - |
$409 11,370 kWh |
$237 18 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,097 Cost: $217,542 |
$12,528 | 350,275 | $7,928 | 608 | $32,942 | 6,472 | $831 | - | $868 | - | $12,528 350,275 kWh |
$7,928 608 kW-months/year |
$32,942 6,472 MMBtu |
$831 - $ |
$868 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |