Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2006 |
Principal Product | Air-Cooled Evaporators |
NAICS | 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 215 |
Plant Area (Sq.Ft.) | 283,504 |
Annual Production | 100,000 Pieces |
Production Hrs. Annual | 7,324 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $280,124 | 4,130,412 | kWh | $0.07 |
Electricity Demand | $40,915 | 9,525 | kW-months/year | $4.30 |
Electricity Fees | $2,207 | - | $ | - |
Natural Gas | $100,733 | 10,313 | MMBtu | $9.77 |
TOTAL ENERGY COSTS | $455,357 | |||
RECOMMENDED SAVINGS* | $128,931 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $69,707 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $61,122 Cost: $180,000 |
$53,612 | 788,414 | $5,556 | 1,292 | - | - | $(-2,294) | - | $4,248 | - |
$53,612 788,414 kWh |
$5,556 1,292 kW-months/year |
- - MMBtu |
$(-2,294) - $ |
$4,248 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,585 Cost: $53,959 |
$6,473 | 95,198 | $1,027 | 237 | - | - | $329 | - | $756 | - |
$6,473 95,198 kWh |
$1,027 237 kW-months/year |
- - MMBtu |
$329 - $ |
$756 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,649 Cost: $1,500 |
$2,649 | 38,999 | - | - | - | - | - | - | - | - |
$2,649 38,999 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $6,565 Cost: - |
- | - | - | - | $6,565 | 672 | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,565 672 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $44,224 Cost: $56,250 |
$9,515 | 139,929 | $3,509 | 816 | - | - | - | - | $31,200 | - |
$9,515 139,929 kWh |
$3,509 816 kW-months/year |
- - MMBtu |
- - $ |
$31,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1224 REPLACE BOILER |
Savings: $4,755 Cost: $27,175 |
- | - | - | - | $2,755 | 282 | $2,000 | - | - | - |
- - kWh |
- - kW-months/year |
$2,755 282 MMBtu |
$2,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,031 Cost: - |
$911 | 13,400 | $120 | 28 | - | - | - | - | - | - |
$911 13,400 kWh |
$120 28 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $128,931 Cost: $318,884 |
$73,160 | 1,075,940 | $10,212 | 2,373 | $9,320 | 954 | $35 | - | $36,204 | - | $73,160 1,075,940 kWh |
$10,212 2,373 kW-months/year |
$9,320 954 MMBtu |
$35 - $ |
$36,204 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $69,707 Cost: $233,959 |
$60,085 | 883,612 | $6,583 | 1,529 | - | - | $(-1,965) | - | $5,004 | - | $60,085 883,612 kWh |
$6,583 1,529 kW-months/year |
- - MMBtu |
$(-1,965) - $ |
$5,004 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |