Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2009 |
Principal Product | Flat Rolled Carbon |
NAICS | 423510 - Metal Service Centers and Other Metal Merchant Wholesalers |
SIC | 5051 - Metals Service Centers And Offices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 88,525 |
Annual Production | 80,000 Tons |
Production Hrs. Annual | 3,514 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $108,658 | 1,247,676 | kWh | $0.09 |
Electricity Demand | $19,298 | 3,759 | kW-months/year | $5.13 |
Electricity Fees | $4,480 | - | $ | - |
Natural Gas | $85,523 | 8,368 | MMBtu | $10.22 |
TOTAL ENERGY COSTS | $217,959 | |||
RECOMMENDED SAVINGS* | $13,285 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,824 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $393 Cost: $686 |
$128 | 1,472 | $10 | 2 | - | - | $111 | - | $144 | - |
$128 1,472 kWh |
$10 2 kW-months/year |
- - MMBtu |
$111 - $ |
$144 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $177 Cost: - |
$147 | 1,687 | $30 | 6 | - | - | - | - | - | - |
$147 1,687 kWh |
$30 6 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,880 Cost: - |
$2,397 | 27,547 | $483 | 94 | - | - | - | - | - | - |
$2,397 27,547 kWh |
$483 94 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $196 Cost: - |
$196 | 2,255 | - | - | - | - | - | - | - | - |
$196 2,255 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,265 Cost: $1,495 |
$4,265 | 49,020 | - | - | - | - | - | - | - | - |
$4,265 49,020 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6125 KEEP EQUIPMENT CLEAN |
Savings: $2,325 Cost: - |
- | - | - | - | $2,565 | 251 | $(-240) | - | - | - |
- - kWh |
- - kW-months/year |
$2,565 251 MMBtu |
$(-240) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $2,800 Cost: - |
- | - | - | - | $2,800 | 274 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,800 274 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $249 Cost: - |
$157 | 1,800 | $92 | 18 | - | - | - | - | - | - |
$157 1,800 kWh |
$92 18 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,285 Cost: $2,181 |
$7,290 | 83,781 | $615 | 120 | $5,365 | 525 | $(-129) | - | $144 | - | $7,290 83,781 kWh |
$615 120 kW-months/year |
$5,365 525 MMBtu |
$(-129) - $ |
$144 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,824 Cost: $686 |
$2,829 | 32,506 | $615 | 120 | $5,365 | 525 | $(-129) | - | $144 | - | $2,829 32,506 kWh |
$615 120 kW-months/year |
$5,365 525 MMBtu |
$(-129) - $ |
$144 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |