IAC logo
IAC Assessment: IC0167
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0167
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2009
Principal Product Sterile Water
NAICS 423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
SIC 5047 - Medical And Hospital Equipment
Sales $5,000,000-$10,000,000
# of Employees 100
Plant Area (Sq.Ft.) 91,800
Annual Production 66,000,000 Pieces
Production Hrs. Annual 8,520
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $361,278 5,008,052 kWh $0.07
Electricity Demand $50,792 9,459 kW-months/year $5.37
Natural Gas $201,684 20,626 MMBtu $9.78
TOTAL ENERGY COSTS $780,106
RECOMMENDED SAVINGS* $21,720 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,318
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Natural Gas Water Disposal Personnel Changes Primary Raw Material
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,950
Cost:
$19,296
$5,876 81,632 $1,006 188 - - - - $(-39) - $107 - $5,876
81,632
kWh
$1,006
188
kW-months/year
-
-
MMBtu
-
-
Tgal
$(-39)
-
$
$107
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,522
Cost:
$458
$313 4,352 $32 6 - - - - $440 - $737 - $313
4,352
kWh
$32
6
kW-months/year
-
-
MMBtu
-
-
Tgal
$440
-
$
$737
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$7,193
Cost:
-
- - - - $7,193 737 - - - - - - -
-
kWh
-
-
kW-months/year
$7,193
737
MMBtu
-
-
Tgal
-
-
$
-
-
$
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$875
Cost:
$400
- - - - $830 85 $45 8,223 - - - - -
-
kWh
-
-
kW-months/year
$830
85
MMBtu
$45
8,223
Tgal
-
-
$
-
-
$
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$1,524
Cost:
$1,260
- - - - $1,524 156 - - - - - - -
-
kWh
-
-
kW-months/year
$1,524
156
MMBtu
-
-
Tgal
-
-
$
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$137
Cost:
$115
$137 1,907 - - - - - - - - - - $137
1,907
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
-
-
$
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$3,067
Cost:
$8,134
$3,067 42,600 - - - - - - - - - - $3,067
42,600
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
-
-
$
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$452
Cost:
-
$259 3,600 $193 36 - - - - - - - - $259
3,600
kWh
$193
36
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$21,720
Cost:
$29,663
$9,652 134,091 $1,231 230 $9,547 978 $45 8,223 $401 - $844 - $9,652
134,091
kWh
$1,231
230
kW-months/year
$9,547
978
MMBtu
$45
8,223
Tgal
$401
-
$
$844
-
$
TOTAL IMPLEMENTED Savings:
$14,318
Cost:
$10,367
$3,517 48,859 $32 6 $9,547 978 $45 8,223 $440 - $737 - $3,517
48,859
kWh
$32
6
kW-months/year
$9,547
978
MMBtu
$45
8,223
Tgal
$440
-
$
$737
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $ $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Natural Gas Water Disposal Personnel Changes Primary Raw Material