Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2009 |
Principal Product | Sterile Water |
NAICS | 423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers |
SIC | 5047 - Medical And Hospital Equipment |
Sales | $5,000,000-$10,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 91,800 |
Annual Production | 66,000,000 Pieces |
Production Hrs. Annual | 8,520 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $361,278 | 5,008,052 | kWh | $0.07 |
Electricity Demand | $50,792 | 9,459 | kW-months/year | $5.37 |
Natural Gas | $201,684 | 20,626 | MMBtu | $9.78 |
TOTAL ENERGY COSTS | $780,106 | |||
RECOMMENDED SAVINGS* | $21,720 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,318 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,950 Cost: $19,296 |
$5,876 | 81,632 | $1,006 | 188 | - | - | - | - | $(-39) | - | $107 | - |
$5,876 81,632 kWh |
$1,006 188 kW-months/year |
- - MMBtu |
- - Tgal |
$(-39) - $ |
$107 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,522 Cost: $458 |
$313 | 4,352 | $32 | 6 | - | - | - | - | $440 | - | $737 | - |
$313 4,352 kWh |
$32 6 kW-months/year |
- - MMBtu |
- - Tgal |
$440 - $ |
$737 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $7,193 Cost: - |
- | - | - | - | $7,193 | 737 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,193 737 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $875 Cost: $400 |
- | - | - | - | $830 | 85 | $45 | 8,223 | - | - | - | - |
- - kWh |
- - kW-months/year |
$830 85 MMBtu |
$45 8,223 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,524 Cost: $1,260 |
- | - | - | - | $1,524 | 156 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,524 156 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $137 Cost: $115 |
$137 | 1,907 | - | - | - | - | - | - | - | - | - | - |
$137 1,907 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $3,067 Cost: $8,134 |
$3,067 | 42,600 | - | - | - | - | - | - | - | - | - | - |
$3,067 42,600 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $452 Cost: - |
$259 | 3,600 | $193 | 36 | - | - | - | - | - | - | - | - |
$259 3,600 kWh |
$193 36 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,720 Cost: $29,663 |
$9,652 | 134,091 | $1,231 | 230 | $9,547 | 978 | $45 | 8,223 | $401 | - | $844 | - | $9,652 134,091 kWh |
$1,231 230 kW-months/year |
$9,547 978 MMBtu |
$45 8,223 Tgal |
$401 - $ |
$844 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,318 Cost: $10,367 |
$3,517 | 48,859 | $32 | 6 | $9,547 | 978 | $45 | 8,223 | $440 | - | $737 | - | $3,517 48,859 kWh |
$32 6 kW-months/year |
$9,547 978 MMBtu |
$45 8,223 Tgal |
$440 - $ |
$737 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Primary Raw Material |