Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2010
Principal Product electric motor control centers
NAICS 335314 - Relay and Industrial Control Manufacturing
SIC 3625 - Relays And Industrial Controls
Sales $100,000,000-$500,000,000
# of Employees 300
Plant Area (Sq.Ft.) 170,000
Annual Production 6,073,500 Pieces
Production Hrs. Annual 6,424
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $250,975 3,362,122 kWh $0.07
Electricity Demand $50,115 691 kW-months/year $72.53
Natural Gas $115,603 19,304 MMBtu $5.99
TOTAL ENERGY COSTS $436,301
RECOMMENDED SAVINGS* $32,097 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$5,695
Cost:
$76
- - - - $5,695 835 - - - - -
-
kWh
-
-
kW-months/year
$5,695
835
MMBtu
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$867
Cost:
$627
$456 6,086 $50 1 - - $82 - $279 - $456
6,086
kWh
$50
1
kW-months/year
-
-
MMBtu
$82
-
$
$279
-
$
03: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT Savings:
$9,779
Cost:
$2,404
$(-3,371) (-44,942) $(-1,070) (-14,764) $14,220 2,085 - - - - $(-3,371)
(-44,942)
kWh
$(-1,070)
(-14,764)
kW-months/year
$14,220
2,085
MMBtu
-
-
$
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$14,765
Cost:
$1,956
$14,765 196,865 - - - - - - - - $14,765
196,865
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$991
Cost:
-
$893 11,900 $98 1 - - - - - - $893
11,900
kWh
$98
1
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$32,097
Cost:
$5,063
$12,743 169,909 $(-922) (-14,762) $19,915 2,920 $82 - $279 - $12,743
169,909
kWh
$(-922)
(-14,762)
kW-months/year
$19,915
2,920
MMBtu
$82
-
$
$279
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost